The Megger EZ-Thump 4 kV is a compact, high-energy fault location solution developed for low-voltage (LV) power networks. The system delivers a single-stage 500 J surge at 4.0 kV, an integrated time-domain reflectometer (TDR) with a range of up to 7.6 km, and Arc Reflection Method (ARM) testing. Sheath fault testing and sheath fault location are also supported.
The Easy Go test system simplifies testing by guiding the user through each stage and automatically interpreting results. Automatic end-of-cable and fault detection reduces setup time, while a transflective colour display provides clear visibility in varied lighting conditions. The EZ-Thump 4 kV incorporates the F-OHM high-voltage interlock to verify correct earthing before testing is permitted. The unit supports both AC mains and internal battery operation, and weighs 32 kg.
| EZT3DV3 | EZT4V3 | EZT12V3 | |
|---|---|---|---|
| MV Buried Cable Fault Locating | ■ | ||
| LV Sheilded Buried Cable Fault Locating | Best | Good | OK |
| LV UNsheilded Buried Cable Fault Locating | Best | Good | OK |
| Street Light Fault Locating | Best | Good | OK |
| Sectionalising Networks | Up to 3KV | Up to 4KV | Up to 12KV |
| Solar Buried and Tray Cable Fault Locating | Best | Good | OK |
| Insulation Testing | 3KV | 4KV | 12KV |
| Time Domain Reflectometry (TDR) | ■ | ■ | ■ |
| Conditioning Cables | 94mA | 35mA | 12mA |
| Sheath Testing | ■ | ■ | ■ |
Call 01642 931 329 or complete the form:
Automatically adds to your basket when the total exceeds £250+ (ex VAT). Limited Stock. More details here.
| EZT3DV3 1.5KV/3KV |
EZT4V3 4KV |
EZT12V3 12KV |
|
|---|---|---|---|
| Supply | |||
| AC Supply | AC line: 100-230 VAC ±50/60 Hz | AC line: 100-230 VAC ±50/60 Hz | AC line: 100-230 VAC ±50/60 Hz |
| Battery | Internal 24 V, NiMH Battery 5 AH | ||
| Battery Charge | Approx. 30-60 min of surge/thumping | ||
| Battery Charger | Internal, 100-240 VAC-24 VDC charger | ||
| Battery Recharge | Approx. 3 hours | ||
| Features | |||
| Hipot | 3KV | 4KV | 12KV |
| Output | 0-1.5 - 47mA 0-3 kV - 94 mA DC |
0-4 - 35 mA DC | 12 mA |
| TDR | On-screen comparison of upto 256 pairs | ||
| TDR Range | Up to 170,000 ft / 52km | ||
| TDR Sampling Rate | 100 Mhz | ||
| TDR Resolution | 2.5 ft @ 250 ft/fs (0.8m @ 80 m/μs) | ||
| Automatic End of Cable and Distance to Fault Indication | ■ | ■ | ■ |
| Arc Reflection | Single-shot surge, multishot TDR, 0-1.5/0-3kV | Single-shot surge, multishot TDR, 0-4kV | Single-shot surge, multishot TDR, 0-12kV |
| Surge | 0-1.5/3.0 kV @ 500 J | 0-4 kV @ 500 J | 0-12 kV @ 500 J |
| Impulse Sequence | 5-10 seconds or single shot | ||
| Sectionalisation | Optional | ||
| Sheath Testing and Sheath Fault Locating | ■ | ■ | ■ |
| E-tray (Step-by-step customisable fault locating) | ■ | ■ | ■ |
| Hardware | |||
| Display | 7in (17.78 cm) HiBrite TFT Colour LCD 1280x800 pixel | ||
| Memory | 100 traces | ||
| Interface | USB port | ||
| Terminations | T9 | ||
| Termination Kits | |||
| North American Hot Line Clamps | ■ | ■ | ■ |
| Vice Grip Clamps | ■ | ■ | ■ |
| Battery Clamps | ■ | ■ | ■ |
| Dimensions (Includes top-mounted cable pouch) | 14x11x25 in. (35.5x28x64 cm) | ||
| Weight | 75lbs (34kg) | 71lbs (34kg) | 71lbs (34kg) |
| Safety | |||
| Emergency OFF Mushroom Button | ■ | ■ | ■ |
| Key-switch Interlock, Standard (Available without) | ■ | ■ | ■ |
| F-Ohm Interlock Detection/Indication “Safe Connections” | ■ | ■ | ■ |
| Interface for Remote EMERGENCY OFF Box | ■ | ■ | ■ |
| Environmental | |||
| Operating Temperature | -20ºC to +50ºC (-4ºF to +122ºF) | ||
| Storage Temperature | -25ºC to +65ºC (-13ºF to +149ºF) | ||
| IP Rating | IP53 (with top open) | ||
| Cables Supplied | |||
| AC Supply Lead Set | 6 ft (1.8 m), (US/schuko/UK plug) | ||