  • 5 kV or 10 kV models
  • Measures up to 20 TΩ
  • Up to 3 mA noise rejection
SKU
MEG-MIT-ESS

Read More

View All High Voltage Insulation Testers & Megohmmeters

The Megger Essential Range includes the MIT515/2 and MIT1015 models. These portable, high-precision insulation resistance testers are ideal for maintaining and testing high-voltage systems. The Essential Range has straightforward ‘go/no-go’ diagnostics, a 3 mA burn current, and guard terminals.

Both models have insulation resistance (IR), dielectric absorption ratio (DAR), and polarisation index (PI) testing functions. The unique PI Predictor technology reduces PI test duration to roughly half the standard time. The MIT515/2 tests voltages up to 5 kV, and the MIT1015 up to 10 kV.

Product Range

  • Megger MIT515/2 Essential Range Insulation Resistance Tester, 5 kV
  • Megger MIT1015 Essential Range Insulation Resistance Tester, 10 kV

Key Features

  • PI Predictor TM boosts testing productivity
  • Dependable results in noisy environments
  • Comprehensive test modes
  • High performance guard terminal
  • Safety rated up to CAT IV
  • Reliable performance for routine testing
  • RE>Act mode enhanced accuracy and safety
  • Measures up to 20 TΩ
  • Up to 3 mA noise rejection
  • Unique dual-case design – additional user protection
  • Operates from battery or AC mains supply
  • Rapid charge Li-ion battery

Feature Comparison

Essential Advanced Expert
Test Capability High Guard Terminal Performance
IR
IR(t)
PI Polarisation Index
PI Predictor
DAR Dielectric Absorption Ratio
DD Dielectric Discharge
Ramp Test
RE>Act Mode
PDC Test
Test Voltage Max. Voltages Available 5 kV or 10 kV 5 kV, 10 kV or 15 kV 5 kV, 10 kV or 15 kV
Charging and Burn Mode Current Default Maximum Current 3 mA 3 mA 6 mA
User Selectable Max. Current Values N/A 1 mA, 3 mA, 6 mA (6 mA only from mains supply) 1 mA, 2 mA, 3 mA, 4 mA, 5 mA, 6 mA (6 mA from internal battery and mains supply)
Noise Immunity Max. Noise Current with Measurement within Accuracy Spec. 3 mA (LV and MV <45 kV) 6 mA (HV <230 kV) 8 mA (EHV <1000 kV)
Adaptive Filter
Negative Current Handling
Averaging Filter
Safety CAT IV 1000 V
CAT IV 600 V
Hazardous Peak Voltage Detection During IR Measurement
Data Storage / Features On Board - Time Stamped
Temperature Value Stored
Humidity Value Stored
Communications Test Result Transfer via Wired USB
Test Results Transfer via Wireless Bluetooth LE
Test Result Live Streaming via Wired USB
Test Result Live Streaming via Wireless Bluetooth LE
Remote Control via Wired USB
Display New Custom Colour Display
Accessories Carry All Holdall
Deeper Lid Pouch
Software Support CertSuite Asset Lite FREE
CertSuite Asset compatible
Power DB Lite FREE
Power DB Advance or Pro support

What's Included?

  • Choice of Tester
  • Power lead
  • Calibration certificate
  • Lead set 3kV 3 x 3 m, with medium clips
  • Lead set HV 3 x 3 m, with medium and large clips (MIT1015 only)
  • Fused test probe and clip lead set
  • Control circuit test set
£2,544.00
£3,052.80 inc vat
Free Delivery*
Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
Free Tyre Inflator (Spend £500+) Find Out More

Ask An Expert
Price Match

Offers

Free Tyre Inflator (Spend £500+)

Worth £29.99. Automatically adds to your basket when the total exceeds £500+ (ex VAT). Limited Stock. More details here.

Technical Information
Specification
  MIT515/2 MIT1015
AC Voltage (Auto-Ranging) 90-264 V rms, 47- 63 Hz 100 VA
Battery Charge Time 2.5 hours deep discharge
2 hours normal discharge
Battery Voltage 10.8 V, 5.2 Ah Li-ion batteries, meet IEC 62133:2003
Battery Life 6 hours (typical) continuous testing at 5 kV with a 100 MΩ load 4.5 hours (typical) continuous testing at 10 kV with a 100 MΩ load
Auto Power Off The instrument turns off after a few minutes if not used to conserve battery life
30 Min Quick Charge 1 hour operation at 5 kV with a 100 MΩ load
Test Voltage 250 V, 500 V, 1000 V, 2500 V, 5000 V, User-defined test voltage 500 V, 1000 V, 2500 V, 5000 V, 10000 V, User-defined test voltage
User-Defined Test Voltage 40 V to 1 kV in 10 V steps 40 V to 1 kV in 10 V steps
Test Voltage Accuracy +4%, -0%, ±10 V nominal test voltage at 1 GΩ load (0 °C to 30 °C)
Resistance Range 10 kΩ to 15 TΩ @ 5 kV
10 kΩ to 20 TΩ @ 10 kV
Re<Act Re-absorption current measurement nominal accuracy
Operational up to 30 V externally applied
Accuracy
(23 °C) from 1 MΩ to
5000 V 2500 V 1000 V 500 V 250 V
±5% 1 TΩ 500 GΩ 200 GΩ 100 GΩ 50 GΩ
±20% 10 TΩ 5 TΩ 2 TΩ 1 TΩ 500 GΩ
10 kV 5000 V 2500 V 1000 V 500 V
±5% 2 TΩ 1 TΩ 500 GΩ 200 GΩ 100 GΩ
±20% 20 TΩ 10 TΩ 5 TΩ 2 TΩ 1 TΩ
Guard Terminal Performance When measuring an insulation resistance of 100 GΩ at 5000 V, the tester can guard out current IG at least 5000 times the insulation test current IL with a maximum additional resistance error of 1%.
Display Analogue 100 kΩ to 10 TΩ
Digital 10 kΩ to 10 TΩ 10 kΩ to 20 TΩ
Short Circuit / Charge Current 3 mA @ 5 kV, 10 kV
Insulation Test Alarm 100 kΩ to 10 GΩ
Capacitor Charge <3 s/μF at 3 mA to 5 kV <5 s/μF at 3 mA to 10 kV
Capacitor Discharge <250 ms/μF to discharge from 5 kV to 50 V <250 ms/μF to discharge from 10 kV to 50 V
Capacitance Range With test voltage set above 500 V - 10 nF to 25 μF
Capacitance Measurement Accuracy ±10% ±5 nF
Current Range 0.01 nA to 6 mA
Current Accuracy ±5% ±0.2 nA at all voltages (20 °C)
Interference 3 mA from 450 V to 5 kV 3 mA from 960 V to 10 kV
Voltmeter Range 30 V to 660 V AC or DC, 45 Hz – 65 Hz
Voltmeter Accuracy ±3%, ±3 V
Timer Range Up to 99 minutes 59 seconds, 15-second minimum setting
Test Modes IR, IR(t), DAR, PI
Maximum Altitude 3000 m (5 kV, 10 kV)
Operating Temperature Range -20 °C to 50 °C
Storage Temperature Range -25 °C to 65 °C
Humidity 90% RH non-condensing at 40 °C
IP Rating IP65 (lid closed), IP40 (lid open)
Safety CAT IV 600 V to 3000 m altitude
Dimensions L 315 mm x W 285 mm x H 181 mm

 