The Metrel MD9226 True-RMS AC/DC Current Clamp Meter has a 35mm jaw and is suitable for system maintenance, power system checking, high-level industrial testing and high-level electrical testing. It can be used to measure a variety of electrical parameters including:
This current clamp meter is also suitable for conducting diode tests and acoustic continuity tests. Moreover, the Metrel MD9226 True-RMS AC/DC Current Clamp Meter will perform automatic, non-contact electromagnetic field detection allowing the user to find and trace live conductors.
Additionally, the Metrel MD9226 True-RMS AC/DC Current Clamp Meter is auto-ranging and includes a built-in VFD feature which ensures that the instrument is capable of measuring true values in reference to frequency.
It is possible to retain the most current measurement on the Metrel MD9226 True-RMS AC/DC Current Clamp Meter’s backlit, 6000-count, LCD display by engaging the Data Hold function. The Metrel MD9226 True-RMS AC/DC Current Clamp Meter also includes MIN/MAX/AVG, Peak Value and Relative Zero functions, allowing the user to determine and view the measurement most relevant to his/her application.
The Metrel MD9226 True-RMS AC/DC Current Clamp Meter also includes an Auto-Power-Off function.
Finally, the Metrel MD9226 True-RMS AC/DC Current Clamp Meter has a CAT IV / 300 V, CAT III / 600V overvoltage safety rating and is equipped with a robust, industrial-grade casing. The Metrel MD9226 True-RMS AC/DC Current Clamp Meter is a versatile, reliable and durable instrument.
Function | Range | Accuracy |
DC Voltage | 600.0 V | ±(1.0% of reading + 5 digits) |
AC Voltage (50 Hz … 60 Hz) | 600.0 V | ±(1.0% of reading + 5 digits) |
DC+AC Voltage (DC, 50 Hz … 60 Hz) | 600.0 V | ±(1.2% of reading + 7 digits) |
PEAK-rms (ACV & ACA) | Response: 80 ms to > 90% | |
Audible Continuity Tester | Audible Threshold: At between 10 Ω and 250 Ω. | Response time: 32ms approx. |
Ohm | 600.0 Ω, 6.000 kΩ, 60.00 kΩ | ±(1.0% of reading + 5 digits) |
Capacitance | 200.0 ΩF, 2500 ΩF | ±(2.0% of reading + 4 digits) |
Diode Tester | 2.000 V | ±(1.5% of reading + 5 digits) |
AmpTipTM clamp-on ACA (50 Hz … 60 Hz) | 60.00 A | ±(1.5% of reading + 5 digits) |
AmpTipTM clamp-on DCA | 60.00 A | ±(2.0% of reading + 5 digits) |
AmpTipTM clamp-on DC+ACA (DC, 50 Hz … 60 Hz) | 60.00 A | ±(2.0% of reading + 7 digits) |
Regular Clamp-on ACA (50 Hz … 400 Hz) | 60.00 A … 600.0 A | From ±(1.8% of reading + 5 digits) to ±(2.0% of reading + 5 digits) |
Regular Clamp-on DCA | 60.00 A … 600.0 A | ±(2.0% of reading + 5 digits) |
Regular Clamp-on DC+ACA (DC, 50 Hz … 400 Hz) | 60.00 A … 600.0 A | From ±(2.2% of reading + 7 digits) to ±(2.7% of reading + 7 digits) |
Hz Line Level Frequency | 5.00 Hz … 999.9 Hz | ±(1.0% of reading + 5 digits) |
Non-Contact EF-Detection | 20 V … 440 V | Tolerance: 10 V … 600 V |
Detection Frequency | 50/60 Hz | |
Transient Protection | 6.0 kV (1.2/50 µs surge) | |
Overload Protections | Current & Hz functions via jaws: 600 A DC/ A AC rms at < 400 Hz Other functions via terminals: 600 V DC / V AC rms | |
Power Supply | 1.5 V AAA Size battery X 2 | |
Power Consumption | 13 mA | |
Dimension (L x W x H) | 223 x 76 x 37 mm | |
Weight | 234 g | |
Jaw opening & Conductor diameter | 35 mm | |
Standards | CAN/CSA C22.2 No. 61010-1 Ed. 3.0 | |
EN61326-1:2006 | ||
EN55022 | ||
EN61000-3-2 | ||
EN61000-3-3 | ||
EN61000-4-2 | ||
EN61000-4-3 | ||
EN61000-4-4 | ||
EN61000-4-5 | ||
EN61000-4-6 | ||
EN61000-4-8 | ||
EN61000-4-11 | ||
IEC/UL/EN61010-1 Ed. 3.0 | ||
IEC/EN61010-2-033 Ed. 1.0 | ||
IEC/EN61010-2-032 Ed. 3.0 | ||
IEC/EN61010-031 Ed. 1.1 | ||
Directives | 2004/108/EC EMC | |
2006/95/EC LVD |