Metrel MI 3152 Multifunction Tester

The Metrel MI 3152 EurotestXC Multifunction Tester represents the latest generation of Metrel’s multifunctional measuring instruments. It retains well-known features such as comprehensive installation safety testing in accordance with IEC/EN 61557 and AUTO SEQUENCE testing for TN, TT, and IT earthing systems, all managed through a new user interface with a large colour touchscreen display.

The device offers a comprehensive range of functions, including online voltage monitoring, phase sequence testing, earth resistance measurement, illuminance measurement, and TRMS current measurement. It also performs RCD tests, line and loop impedance tests, earth resistance measurements, ISFL measurements, and IMD tests.

Key Features

  • Predefined Automatic tests:
    • Auto TT (U, Zln, Zs, Uc);
    • Auto TN/RCD (U, Zln, Zs, Rpe)
    • Auto TN (U, Zln, Zlpe, Rpe)
    • Auto IT (U, Zln, Isc, Isfl, IMD)
  • Built-in help screens for referencing on site.
  • Built-in fuse tables for automatic evaluation of the line/loop impedance result.
  • Monitoring of all 3 voltages in real-time.
  • Automatic polarity reversal on continuity test.
  • Automated RCD testing procedure.
  • Built-in charger and rechargeable batteries as standard accessory.
  • BT communication with PC, Android tablets and smartphones via built-in BT.
  • PC SW Metrel ES Manager for creation of test structures and uploading, downloading of test results and report creation.
  • Support for aMESM Android APP and data management tool (option).
  • Dimensions (w x h x l): 230 x 103 x 115 mm.
  • Mass (without accessories): 1.3 kg.

Metrel A 2214 Ring Continuity Adapter

The Metrel A 2214 Ring Continuity Adapter measures continuity in ring final circuits. It automatically conducts r1, rn, r2, and R1 + RN, R1 + R2 measurements.

The A 2214 quickly connects to the distribution board's colour-coded L, N, and PE wires. Managed by the tester, it conducts all required ring continuity tests. This streamlined method significantly simplifies and reduces the time needed for comprehensive testing of ring final circuits.

Key Features

  • Automated continuity testing (patented) of ring final circuits: r1, rn, r2 and R1+RN, R1+R2.
  • Live, neutral and PE resistance are all measured at the press of a button.
  • Automatic calculation of (r1+rn)/4 and (r1+r2)/4 for easy results evaluation.
  • Connected once, no need to change leads until all continuity tests are complete.
  • Quick, efficient and easy. Optimize and significantly speed up (up to 60% or more) continuity tests of ring final circuits.
  • Safety, no risk of forgotten connections.
  • Convenience, no need to exchange leads or use connectors.
  • Thoroughness, R1+RN also measured simultaneously.
  • Test speed, connections made by the adapter.
  • Accuracy, with the easy-null capability.
  • Usability can be magnetically attached to the distribution board.

What's Included?

  • Metrel MI 3152 Multifunction Tester
  • Metrel A 2214 Ring Continuity Adapter
  • Test lead, 3 x 1.5 m
  • Power supply adapter
  • 6 NiMH rechargeable batteries, type AA
  • Test probe, 3 pcs (blue, brown, green)
  • Crocodile clip, 3 pcs (blue, brown, green)
  • RS232 - PS/2 cable
  • USB cable
  • Soft carrying bag
  • Soft carrying neck belt
  • Short instruction manual
  • Instruction manual on CD
  • Handbook on CD
  • Calibration certificate
  • Small soft carrying bag A 1020 (A 2214)
  • Crocodile clip A 1297, brown, 2 pieces (A 2214)
  • Crocodile clip A 1309, green, 2 pieces (A 2214)
  • Crocodile clip A 1310, blue, 2 pieces (A 2214)
  • Battery A 1784, size AA, 1.5V alkaline, 4 pieces (A 2214)
  • Instruction manual (A 2214)

Videos

MI 3152 Multifunction Tester Promotional

Electrical Installation Testing | MI 3152 EurotestXC | Features Overview

A 2214 Ring Continuity Adapter Promotional

A 2214 | Ring Continuity Adapter | Promotional (UK)

£1,598.85
£1,918.62 inc vat
Save £84 £1,683
Free Delivery*
Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
Black Friday Free Gift (Spend £200+) Find Out More


60 Day Returns
Ask a Question or Price Match
Black Friday Fantastic Deals End In 00days00hrs00mins00secs Shop the Deals How Can We Help? Got a question? Our team's ready to help. Looking for something specific? We carry thousands more products than you see here. Ask Our Experts A Question

Offers

Black Friday Free Gift (Spend £200+)

Get a free gift this Black! Even better, this bonus stacks with any other offer.

  • Spend £200+ get a free Head Torch OR
  • Spend £500+ get a free Digital Tyre Inflator

Free item will automatically add to your basket. Limited Stock. Offer is based on ex VAT basket total after discounts and before shipping costs. See Black Friday Offers for details.

Remember: We will not be beaten on price. Contact us if you've seen a cheaper price.

Technical Information
Specification

Metrel MI 3152 Multifunction Tester

Extra Features Workspaces El. LV Installation Safety Modes ✔
Industrial Mode ◉
Medical Mode ✔
EVSE Mode ◉
IT Vehicles / Mobile Units Mode ✔
Lightning Mode ✔
Project Structure ✔
Visual Inspection Mode ✔
Functional Inspection Mode ✔
Auto Tests AUTO TT (U, Zln, Zs, Uc) ✔
AUTO TN/RCD (U, Zln, Zs, Rpe) ✔
AUTO TN (U, Zln, Zlpe, Rpe) ✔
AUTO IT (U, Zln, Isc, Isfl, IMD) ✔
Auto Test Line/Loop Impedance TN/TT ✔
AUTOSEQUENCES AUTOSEQUENCE profile ✔
AUTOSEQUENCE EVSE ◉
AUTOSEQUENCE Barcode testing ✔
PASS/FAIL System Evaluation ✔
On-site Parameter Settings ✔
Automatic test sequences Multitest sequence ✔
Advanced User Interface Colour display ✔
Touch screen ✔
Adaptable user interface ✔
Graphical Help Menus ✔
Database System Built-In ✔
Programmable Memory Structure ✔
Multi-level Memory Organiser ✔
SDK support Upload structure ✔
Upload measurements ✔
Download ✔
Main Features
Voltage AC Frequency ✔
Voltage TRMS ✔
Three Phase 3-Phase system (Phase SEQUENCE) ✔
Differential leakage current ◉
Earth Bond / Continuity PE lead resistance 200 mA 3-wire ✔
Ring Test 200 mA (UK installations) ✔
Ring Auto 200 mA (UK installations) ◉
Max Test Current 7 mA 2-wire ✔
Max Test Current 200 mA 2-wire ✔
Automatic polarity reversal ✔
Insulation Resistance Test Voltage 50 V ✔
Test Voltage 100 V ✔
Test Voltage 250 V ✔
Test Voltage 500 V ✔
Test Voltage 1000 V ✔
Test of IMD ✔
Test of ELM ✔
DC Ramp Voltage Test/Varistor test ✔
Automatic Discharge ✔
Leakage Current Differential Leakage ◉
Leakage Current (with optional Clamp) ◉
ISFL: L1, L2 (First Fault Leakage) ✔
AC Insulation Leakage ✔
Z Line / Loop Impedance Zline L-L, L-N Ipsc - 3 Wire ✔
Zline L-L, L-N Ipsc - 2 Wire ✔
Zloop L-PE, Ipfc - 3 Wire ✔
Zloop L-PE, Ipfc - 2 Wire ✔
Zs (rcd) - 3 Wire ✔
Zref, ΔU% ✔
Fuse Tables ✔
Max. Ipfc = 20kA ✔
RCD RCD type AC ✔
RCD type A ✔
RCD type F ✔
RCD type B ✔
RCD type B+ ✔
RCD Uc ✔
RCD (t) ✔
10 mA ✔
30 mA ✔
100 mA ✔
300 mA ✔
500 mA ✔
1000 mA ✔
RCD I Ramp ✔
RCD Auto ✔
RCD 3-Phase ✔
EV-RCD ✔
MI-RCD ✔
RCD-S (Selective) ✔
PRCD PRCD-S, PRCD-K ✔
Earth (Electric) Leakage Relay ◉
Earth/Ground Resistance Earth Resistance 2-wire ✔
Earth Resistance 3-wire ✔
Wenner 4-wire Specific Earth Resistance ◉
Two Iron Clamps Earth Resistance ◉
Functional test and troubleshooting Load test ✔
Power Measurements Active power ✔
Reactive power ✔
Apparent power ✔
Power factor ✔
Harmonics Analysis THD current ✔
THD voltage ✔
Current harmonics ✔
Voltage harmonics ✔
EVSE measurements Monitoring of voltage ◉
Monitoring of current ◉
Simulation of external load ◉
Additional Features Cable location Cable location ◉
Hand-Held Hand-Held ✔
Security User Accounts ✔
PASS / FAIL Indicators PASS/FAIL Indicators ✔
Voltage Monitoring Voltage Monitoring ✔
Display LCD ✔
Back Light ✔
Keyboard QWERTY Keyboard ✔
Virtual Keyboard ✔
Power Supply Rechargeable Batteries in standard delivery ✔
Battery Powered ✔
Power Supply 115 V (50-60Hz) ✔
Power Supply 230 V (50-60Hz) ✔
Mains Supply / PE Check ✔
Test Lead Compensation Test Lead Compensation ✔
Buzzer Buzzer ✔
Graphical user interface Graphical Online Help ✔
Communication Port Communication Port USB ✔
Communication Port RS232 - PS/2 ✔
Built-in Bluetooth Built-in Bluetooth ✔
Mobile Application Android Application ✔
Printing / Scanning QR-Code Printing / Scanning ◉
Memory Internal memory ✔
microSD memory card ✔
Downloadable ✔
Uploadable ✔
IP protection IP 40 ✔
Protection category CAT IV 300 V ✔
CAT III 600 V ✔
Special Accessories EVSE adapter A 1832 Mode 3 Charging cable adapter ✔
Passive 3-Phase Adapter Passive 3-Phase Adapter ◉
Active Impedance Adapter Active Impedance Adapter ◉
Adapter for specific resistance ρ ρ adapter ◉
Active Euro Checkbox Active Euro Checkbox ◉
Active Ring Adapter EASYswitch Active Ring Adapter EASYswitch (UK only) ◉
Cable Locator Cable Locator ◉
Tip Commander Tip Commander ◉
Plug Commander Plug Commander ✔
Current clamps DC - Current Clamp ◉
Generator Current Clamp ◉
AC Leakage Current Clamp ◉
Lux Sensor Lux Sensor ◉
Smartphones scanner Smartphones scanner ◉
PC Software Package PC Software Package ✔
MESM Compatible ✔
Report creation ◉
Professional reporting ◉
Battery Charger Battery Charger ✔
Electrical Energetics Power generation Earthing and lightning protection in thermal energy power plants ✔
Renewable energy sources Generator stator testing ✔
Lightning protection testing in wind plants ✔
Two-clamp method for measuring earth loops in a solar plant ✔
Power distribution Insulation of long cables ✔
Industrial installations Remote antenna tower earthing resistance ✔
Specific earth resistance measurement methods ◉
Building Facilities Low voltage electrical installation safety Substation electrical safety ✔
Mains bonding and touch voltages during fault ✔
Switchboards and automatic trip-out protection ✔
Public places electrical safety ✔
Low voltage earthing and lightning protection Earthing measurement with fall of potential method ✔
2-clamps method for measuring lightning and earth protection ✔
Surge protection devices ✔
Special locations Wet and outdoor locations ✔
IT system ✔
DC installations ✔
EVSE construction and testing ✔
Transportation e-Mobility EVSE domestic installation testing ◉
EVSE periodic inspection ◉
Renewable power and car charging ◉
Mobile installations Vehicles with an on-board generator ◉
Emergency response vehicles ✔
Telecommunication equipment in mobile installations ✔
Medical Facilities Hospital earthing and lightning protection Two clamps method for measuring lightning and earth protection ✔
Hospital earthing measurement with fall of potential method ✔
Mains bonding and touch voltages during fault current ✔
Surge protection devices in hospitals ✔
Power supply and power distribution Hospital switchboards and automatic trip-out protection ✔
Surgery rooms or operating theatres Medical IT system ✔
Isolated areas RCDs ✔
Patient recovery rooms and hospital wards Public and workspace electrical safety in healthcare ✔
Electrical safety in hospital wet areas ✔
Secondary power sources in healthcare Generator safety ✔
Ambulances ✔
Field hospital ✔
Standards Applied Building LV Installation EISinsp Competences: Low Voltage Electrical Installation Safety Inspection ✔
EISc Competences: Low Voltage Electrical Installation Safety for Contractors and Maintainers ✔
IEC/EN 60364 Electrical Installations for Buildings series ✔
IEC/EN 60364-6 Electrical Installations for Buildings - Verification ✔
IEC/EN 60364-4-41 Electrical Installations for Buildings - Protection against electric shock ✔
IEC/EN 60755 General safety requirements for residual current operated protective devices ✔
IEC/EN 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) ✔
IEC/EN 61009 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) ✔
IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series ✔
IEC/EN 61557-1 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements ✔
IEC/EN 61557-2 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance ✔
IEC/EN 61557-3 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance ✔
IEC/EN 61557-6 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems ✔
IEC/EN 61557-7 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence ✔
IEC/EN 61557-10 Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring and monitoring of protective measures ✔
VDE 0413 (IEC 61557) Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series ✔
AS / NZ 3017 Electrical installations – Verification guidelines ✔
AS / NZ 3018 Electrical installations - Domestic installations ✔
BS 7671 IEE Wiring Regulations (18th edition) ✔
CEI 64.8 V4 rated electrical equipment not exceeding 1,000 VAC and 1,500V DC ✔
Earthing and lightning protection LPSinsp Competences: Lightning Protection of Buildings Inspection ✔
LPSc Competences: Lightning Protection of Buildings for Contractors and Maintainers ✔
IEC 62305 Protection against Lightning - series ✔
IEC/EN 61557-5 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth ✔
IEC/EN 61557-4 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding ✔
Power quality PQA Competences: Power Quality Analyzing & Reporting ✔
IEC/EN 61557-12 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 12: Power metering and monitoring devices (PMD) ✔
Electrical switchboards safety ESB Competences: Electrical Switchboard Safety Testing ✔
IEC/EN 62271 High-voltage switchgear and controlgear - series ✔
IEC/EN 62271-1 High-voltage switchgear and control gear - Part 1: Common specifications for alternating current switchgear and control gear ✔
IEC/EN 62271-100 High-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers ✔
Mobile Units Electrical Safety eMOB Competences: Electrical LV Installations in Mobile Units Safety ✔
IEC/EN/HD 60364-7-717 Low-voltage electrical installations: Requirements for special installations or locations – Supplies for Electrical Vehicles ✔
ISO 6469-3 - Electrically propelled road vehicles Safety specification Part 3: Electrical safety ✔
Electrical Vehicle Supply Equipment EVSE Competences: Electrical Vehicle Supply Equipment Safety ◉
IEC/EN 61851 Electric vehicle conductive charging system ✔
IEC/EN 62752 In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD) ✔
Medical electrical equipment AS/NZS 3551 Management programs for medical devices ✔
Medical and surgery room installations MEDi Competences: Medical and Surgery Rooms Electrical Installations Safety ✔
Instrument safety towards the user Directive EMC 89/336/EE on electromagnetic compatibility ✔
IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series ✔
IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage ✔
EMC safety IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series ✔
Key ✔ Supported | ◉ Optional

Metrel A 2214 Ring Continuity Adapter

Main Features Earth Bond / Continuity Ring Test 200 mA (UK installations) ✔
Additional Features Power Supply Rechargeable Batteries in standard delivery ✔
Battery Powered ✔
Test Lead Compensation Test Lead Compensation ✔
IP protection IP 40 ✔
Other applications Preventative maintenance Testing ring final circuits ✔
Standards Applied Building LV Installation BS 7671 IEE Wiring Regulations (18th edition) ✔
Instrument safety towards the user IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series ✔
EMC safety IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series ✔
IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements ✔
Document Downloads
Metrel MI 3152XC Multifunction Tester Datasheet Datasheet
Metrel A 2214 Ring Continuity Adapter Datasheet Datasheet
Additional Information
SKU
RINGKIT2
Manufacturer Part Code
RINGKIT2
Country of Origin
Slovenia

Customer Reviews

 
Metrel MI 3152-ES Multifunction Tester & A 2214 Ring Continuity Adaptor
£1,598.85
£1,918.62 inc vat
£1,598.85
£1,918.62 inc vat