Free Tyre Inflator. Spend £1000+ (ex VAT) View

Metrel MI 3152-ES Multifunction Tester & A 2214 Ring Continuity Adaptor

All Metrel Products
  • Metrel MI 3152 Multifunction Tester
  • Automated RCD testing procedure
  • Metrel A 2214 Ring Continuity Adapter
  • No risk of forgotten connections
SKU
RINGKIT2
MPN
RINGKIT2

Read More

View All Multifunction Testers

This entry set kit includes the Metrel MI 3152 Multifunction Tester and the A 2214 Ring Continuity Adaptor, please the 'What's Included?' section for full kit details.

Metrel MI 3152 Multifunction Tester

The Metrel MI 3152 EurotestXC Multifunction Tester represents the latest generation of Metrel’s multifunctional measuring instruments. It retains well-known features such as comprehensive installation safety testing in accordance with IEC/EN 61557 and AUTO SEQUENCE testing for TN, TT, and IT earthing systems, all managed through a new user interface with a large colour touchscreen display.

The device offers a comprehensive range of functions, including online voltage monitoring, phase sequence testing, earth resistance measurement, illuminance measurement, and TRMS current measurement. It also performs RCD tests, line and loop impedance tests, earth resistance measurements, ISFL measurements, and IMD tests.

Key Features

  • Predefined Automatic tests:
    • Auto TT (U, Zln, Zs, Uc);
    • Auto TN/RCD (U, Zln, Zs, Rpe)
    • Auto TN (U, Zln, Zlpe, Rpe)
    • Auto IT (U, Zln, Isc, Isfl, IMD)
  • Built-in help screens for referencing on site.
  • Built-in fuse tables for automatic evaluation of the line/loop impedance result.
  • Monitoring of all 3 voltages in real-time.
  • Automatic polarity reversal on continuity test.
  • Automated RCD testing procedure.
  • Built-in charger and rechargeable batteries as standard accessory.
  • BT communication with PC, Android tablets and smartphones via built-in BT.
  • PC SW Metrel ES Manager for creation of test structures and uploading, downloading of test results and report creation.
  • Support for aMESM Android APP and data management tool (option).
  • Dimensions (w x h x l): 230 x 103 x 115 mm.
  • Mass (without accessories): 1.3 kg.

Metrel A 2214 Ring Continuity Adapter

The Metrel A 2214 Ring Continuity Adapter measures continuity in ring final circuits. It automatically conducts r1, rn, r2, and R1 + RN, R1 + R2 measurements.

The A 2214 quickly connects to the distribution board's colour-coded L, N, and PE wires. Managed by the tester, it conducts all required ring continuity tests. This streamlined method significantly simplifies and reduces the time needed for comprehensive testing of ring final circuits.

Key Features

  • Automated continuity testing (patented) of ring final circuits: r1, rn, r2 and R1+RN, R1+R2.
  • Live, neutral and PE resistance are all measured at the press of a button.
  • Automatic calculation of (r1+rn)/4 and (r1+r2)/4 for easy results evaluation.
  • Connected once, no need to change leads until all continuity tests are complete.
  • Quick, efficient and easy. Optimize and significantly speed up (up to 60% or more) continuity tests of ring final circuits.
  • Safety, no risk of forgotten connections.
  • Convenience, no need to exchange leads or use connectors.
  • Thoroughness, R1+RN also measured simultaneously.
  • Test speed, connections made by the adapter.
  • Accuracy, with the easy-null capability.
  • Usability can be magnetically attached to the distribution board.

What's Included?

  • Metrel MI 3152 Multifunction Tester
  • Metrel A 2214 Ring Continuity Adapter
  • Test lead, 3 x 1.5 m
  • Power supply adapter
  • 6 NiMH rechargeable batteries, type AA
  • Test probe, 3 pcs (blue, brown, green)
  • Crocodile clip, 3 pcs (blue, brown, green)
  • RS232 - PS/2 cable
  • USB cable
  • Soft carrying bag
  • Soft carrying neck belt
  • Short instruction manual
  • Instruction manual on CD
  • Handbook on CD
  • Calibration certificate
  • Small soft carrying bag A 1020 (A 2214)
  • Crocodile clip A 1297, brown, 2 pieces (A 2214)
  • Crocodile clip A 1309, green, 2 pieces (A 2214)
  • Crocodile clip A 1310, blue, 2 pieces (A 2214)
  • Battery A 1784, size AA, 1.5V alkaline, 4 pieces (A 2214)
  • Instruction manual (A 2214)

Videos

MI 3152 Multifunction Tester Promotional

Electrical Installation Testing | MI 3152 EurotestXC | Features Overview

A 2214 Ring Continuity Adapter Promotional

A 2214 | Ring Continuity Adapter | Promotional (UK)

£1,683.00
£2,019.60 inc vat
Free Delivery*
Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.

Ask An Expert
Price Match
Technical Information
Specification

Metrel MI 3152 Multifunction Tester

Extra Features Workspaces El. LV Installation Safety Modes
Industrial Mode
Medical Mode
EVSE Mode
IT Vehicles / Mobile Units Mode
Lightning Mode
Project Structure
Visual Inspection Mode
Functional Inspection Mode
Auto Tests AUTO TT (U, Zln, Zs, Uc)
AUTO TN/RCD (U, Zln, Zs, Rpe)
AUTO TN (U, Zln, Zlpe, Rpe)
AUTO IT (U, Zln, Isc, Isfl, IMD)
Auto Test Line/Loop Impedance TN/TT
AUTOSEQUENCES AUTOSEQUENCE profile
AUTOSEQUENCE EVSE
AUTOSEQUENCE Barcode testing
PASS/FAIL System Evaluation
On-site Parameter Settings
Automatic test sequences Multitest sequence
Advanced User Interface Colour display
Touch screen
Adaptable user interface
Graphical Help Menus
Database System Built-In
Programmable Memory Structure
Multi-level Memory Organiser
SDK support Upload structure
Upload measurements
Download
Main Features
Voltage AC Frequency
Voltage TRMS
Three Phase 3-Phase system (Phase SEQUENCE)
Differential leakage current
Earth Bond / Continuity PE lead resistance 200 mA 3-wire
Ring Test 200 mA (UK installations)
Ring Auto 200 mA (UK installations)
Max Test Current 7 mA 2-wire
Max Test Current 200 mA 2-wire
Automatic polarity reversal
Insulation Resistance Test Voltage 50 V
Test Voltage 100 V
Test Voltage 250 V
Test Voltage 500 V
Test Voltage 1000 V
Test of IMD
Test of ELM
DC Ramp Voltage Test/Varistor test
Automatic Discharge
Leakage Current Differential Leakage
Leakage Current (with optional Clamp)
ISFL: L1, L2 (First Fault Leakage)
AC Insulation Leakage
Z Line / Loop Impedance Zline L-L, L-N Ipsc - 3 Wire
Zline L-L, L-N Ipsc - 2 Wire
Zloop L-PE, Ipfc - 3 Wire
Zloop L-PE, Ipfc - 2 Wire
Zs (rcd) - 3 Wire
Zref, ΔU%
Fuse Tables
Max. Ipfc = 20kA
RCD RCD type AC
RCD type A
RCD type F
RCD type B
RCD type B+
RCD Uc
RCD (t)
10 mA
30 mA
100 mA
300 mA
500 mA
1000 mA
RCD I Ramp
RCD Auto
RCD 3-Phase
EV-RCD
MI-RCD
RCD-S (Selective)
PRCD PRCD-S, PRCD-K
Earth (Electric) Leakage Relay
Earth/Ground Resistance Earth Resistance 2-wire
Earth Resistance 3-wire
Wenner 4-wire Specific Earth Resistance
Two Iron Clamps Earth Resistance
Functional test and troubleshooting Load test
Power Measurements Active power
Reactive power
Apparent power
Power factor
Harmonics Analysis THD current
THD voltage
Current harmonics
Voltage harmonics
EVSE measurements Monitoring of voltage
Monitoring of current
Simulation of external load
Additional Features Cable location Cable location
Hand-Held Hand-Held
Security User Accounts
PASS / FAIL Indicators PASS/FAIL Indicators
Voltage Monitoring Voltage Monitoring
Display LCD
Back Light
Keyboard QWERTY Keyboard
Virtual Keyboard
Power Supply Rechargeable Batteries in standard delivery
Battery Powered
Power Supply 115 V (50-60Hz)
Power Supply 230 V (50-60Hz)
Mains Supply / PE Check
Test Lead Compensation Test Lead Compensation
Buzzer Buzzer
Graphical user interface Graphical Online Help
Communication Port Communication Port USB
Communication Port RS232 - PS/2
Built-in Bluetooth Built-in Bluetooth
Mobile Application Android Application
Printing / Scanning QR-Code Printing / Scanning
Memory Internal memory
microSD memory card
Downloadable
Uploadable
IP protection IP 40
Protection category CAT IV 300 V
CAT III 600 V
Special Accessories EVSE adapter A 1832 Mode 3 Charging cable adapter
Passive 3-Phase Adapter Passive 3-Phase Adapter
Active Impedance Adapter Active Impedance Adapter
Adapter for specific resistance ρ ρ adapter
Active Euro Checkbox Active Euro Checkbox
Active Ring Adapter EASYswitch Active Ring Adapter EASYswitch (UK only)
Cable Locator Cable Locator
Tip Commander Tip Commander
Plug Commander Plug Commander
Current clamps DC - Current Clamp
Generator Current Clamp
AC Leakage Current Clamp
Lux Sensor Lux Sensor
Smartphones scanner Smartphones scanner
PC Software Package PC Software Package
MESM Compatible
Report creation
Professional reporting
Battery Charger Battery Charger
Electrical Energetics Power generation Earthing and lightning protection in thermal energy power plants
Renewable energy sources Generator stator testing
Lightning protection testing in wind plants
Two-clamp method for measuring earth loops in a solar plant
Power distribution Insulation of long cables
Industrial installations Remote antenna tower earthing resistance
Specific earth resistance measurement methods
Building Facilities Low voltage electrical installation safety Substation electrical safety
Mains bonding and touch voltages during fault
Switchboards and automatic trip-out protection
Public places electrical safety
Low voltage earthing and lightning protection Earthing measurement with fall of potential method
2-clamps method for measuring lightning and earth protection
Surge protection devices
Special locations Wet and outdoor locations
IT system
DC installations
EVSE construction and testing
Transportation e-Mobility EVSE domestic installation testing
EVSE periodic inspection
Renewable power and car charging
Mobile installations Vehicles with an on-board generator
Emergency response vehicles
Telecommunication equipment in mobile installations
Medical Facilities Hospital earthing and lightning protection Two clamps method for measuring lightning and earth protection
Hospital earthing measurement with fall of potential method
Mains bonding and touch voltages during fault current
Surge protection devices in hospitals
Power supply and power distribution Hospital switchboards and automatic trip-out protection
Surgery rooms or operating theatres Medical IT system
Isolated areas RCDs
Patient recovery rooms and hospital wards Public and workspace electrical safety in healthcare
Electrical safety in hospital wet areas
Secondary power sources in healthcare Generator safety
Ambulances
Field hospital
Standards Applied Building LV Installation EISinsp Competences: Low Voltage Electrical Installation Safety Inspection
EISc Competences: Low Voltage Electrical Installation Safety for Contractors and Maintainers
IEC/EN 60364 Electrical Installations for Buildings series
IEC/EN 60364-6 Electrical Installations for Buildings - Verification
IEC/EN 60364-4-41 Electrical Installations for Buildings - Protection against electric shock
IEC/EN 60755 General safety requirements for residual current operated protective devices
IEC/EN 61008-1 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs)
IEC/EN 61009 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs)
IEC/EN 61557 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series
IEC/EN 61557-1 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements
IEC/EN 61557-2 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
IEC/EN 61557-3 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance
IEC/EN 61557-6 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems
IEC/EN 61557-7 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence
IEC/EN 61557-10 Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring and monitoring of protective measures
VDE 0413 (IEC 61557) Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - series
AS / NZ 3017 Electrical installations – Verification guidelines
AS / NZ 3018 Electrical installations - Domestic installations
BS 7671 IEE Wiring Regulations (18th edition)
CEI 64.8 V4 rated electrical equipment not exceeding 1,000 VAC and 1,500V DC
Earthing and lightning protection LPSinsp Competences: Lightning Protection of Buildings Inspection
LPSc Competences: Lightning Protection of Buildings for Contractors and Maintainers
IEC 62305 Protection against Lightning - series
IEC/EN 61557-5 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth
IEC/EN 61557-4 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding
Power quality PQA Competences: Power Quality Analyzing & Reporting
IEC/EN 61557-12 Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 12: Power metering and monitoring devices (PMD)
Electrical switchboards safety ESB Competences: Electrical Switchboard Safety Testing
IEC/EN 62271 High-voltage switchgear and controlgear - series
IEC/EN 62271-1 High-voltage switchgear and control gear - Part 1: Common specifications for alternating current switchgear and control gear
IEC/EN 62271-100 High-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers
Mobile Units Electrical Safety eMOB Competences: Electrical LV Installations in Mobile Units Safety
IEC/EN/HD 60364-7-717 Low-voltage electrical installations: Requirements for special installations or locations – Supplies for Electrical Vehicles
ISO 6469-3 - Electrically propelled road vehicles Safety specification Part 3: Electrical safety
Electrical Vehicle Supply Equipment EVSE Competences: Electrical Vehicle Supply Equipment Safety
IEC/EN 61851 Electric vehicle conductive charging system
IEC/EN 62752 In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD)
Medical electrical equipment AS/NZS 3551 Management programs for medical devices
Medical and surgery room installations MEDi Competences: Medical and Surgery Rooms Electrical Installations Safety
Instrument safety towards the user Directive EMC 89/336/EE on electromagnetic compatibility
IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series
IEC/EN 61010-2-033 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
EMC safety IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series
Key ✔ Supported | ◉ Optional

Metrel A 2214 Ring Continuity Adapter

Main Features Earth Bond / Continuity Ring Test 200 mA (UK installations)
Additional Features Power Supply Rechargeable Batteries in standard delivery
Battery Powered
Test Lead Compensation Test Lead Compensation
IP protection IP 40
Other applications Preventative maintenance Testing ring final circuits
Standards Applied Building LV Installation BS 7671 IEE Wiring Regulations (18th edition)
Instrument safety towards the user IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use - series
EMC safety IEC/EN 61326 Electrical equipment for measurement, control and laboratory use - EMC requirements - series
IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
Document Downloads
Metrel MI 3152XC Multifunction Tester Datasheet Datasheet
Metrel A 2214 Ring Continuity Adapter Datasheet Datasheet
Additional Information
SKU
RINGKIT2
Manufacturer Part Code
RINGKIT2
Country of Origin
Slovenia

Customer Reviews

 
Metrel MI 3152-ES Multifunction Tester & A 2214 Ring Continuity Adaptor
£1,683.00
£2,019.60 inc vat
£1,683.00
£2,019.60 inc vat