Read More

The Sonel MZC-320S measures short-circuit loop impedance (ZS) in networks where prospective fault currents can reach extreme levels. It is rated for systems up to 500 V and capable of measuring in installations where fault currents may reach up to 69.4 kA in accordance with EN 61557.

The MZC-320S has a unique fault resistor design for symmetrical measurement and reliable ZS readings down to single milliohm values. This is particularly critical in networks protected by high-current fuse links or motor protection breakers rated at several hundred amperes. The internal ventilation system accelerates the cooling of the short-circuit resistor, and the MZC-320S supports remote control via Wi-Fi.

Unboxing Sonel MZC-320S

Key Features

  • Measurement of very low short circuit loop impedances (with resolution 0,1 mΩ) with a current of 130 A at 230 V; maximum 300 A at 500 V.
  • Measurement with a current of 24 A at 230 V, maximum 27 A at 500 V, with resolution 0,01 Ω.
  • Measurements in installations with rated voltages: 110/190 V, 115/200 V, 127/220 V, 220/380 V, 230/400 V, 240/415 V, 290/500 V and frequencies 45…65 Hz.
  • Ability to perform measurements in a short circuit system: phase-phase, phase-PE, phase-N.
  • Differentiation between the phase voltage and the inter-phase voltage while calculating the short circuit current.
  • Ability to change the length of the test lead (measurement with the 2p method).
  • 4p (four-pole) method, test leads do not require calibration (measurement with current up to 300 A).
  • Measurement of resistance (RS) and reactance (XS) components.
  • Remote control via Wi-Fi: triggering the measurement, saving the result to the meter’s memory, downloading the results from the instrument’s memory.
  • Touch voltage and touch shock voltage measurement with resistor 1 kΩ.
  • AC voltage measurement in range 0…550 V.
  • Frequency measurement 45.0...65.0 Hz.
  • Memory of 990 measurement results, ability to transfer the data to a PC via USB and Bluetooth.
  • Power supply: rechargeable battery

What's Included?

  • MZC-320S Impedance Meter
  • Double-wire test lead 3 m (10 / 25 A)
  • Test lead 1.2 m (banana plugs) black/yellow
  • 2x Kelvin clamp, 1 kV, 25 A
  • 4x crocodile clip 1 kV 32 A black
  • Mains cable 230 V with IEC C7 plug
  • Power supply Z19
  • L14 carrying case
  • Factory calibration certificate
£2,530.00
£3,036.00 inc vat
Free Delivery*
Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
Free Tyre Inflator (Spend £500+) Find Out More


60 Day Returns
Ask a Question or Price Match

Offers

Free Tyre Inflator (Spend £500+)

Automatically adds to your basket when the total exceeds £500+ (ex VAT). Limited Stock. More details here.

Technical Information
Specification
Measurement Functions Measurement Range Display Range Resolution Accuracy
Voltage 0 V…550 V 0 V…550 V 1 V ±(2% m.v. + 2 digits)
Frequency 45.0 Hz…65.0 Hz 45.0 Hz…65.0 Hz 0.1 Hz ±(0.1% m.v. + 1 digit)
Short-Circuit Loop Parameters
4p method - high current measurement, maximum current 300 A 7.2 mΩ…1999 mΩ acc. to EN 61557 0.0 mΩ…1999 mΩ from 0.1 mΩ ±(2% m.v. + 2 mΩ)
2p method - standard current measurement, maximum current 37 A from 0.13 Ω…199.9 Ω acc. to EN 61557 0.00 Ω…199.9 Ω from 0.01 Ω from ±(2% m.v. + 3 digits)
Short-Circuit Current Readings
4p method - high current measurement network voltage 115 V…500 V up to 57.5 A…69.4 kA acc. to EN 61557 115.0 A…500 kA from 0.1 A Calculated based on the error for the fault loop
2p method - standard current measurement from 2.00 A…3.21 kA acc. to EN 61557 1.150 A…40.0 kA from 0.001 A Calculated based on the error for the fault loop
Touch and Shock Voltage
4p method - high current measurement 0 V…100 V 0 V…100 V 1 V ±(10% m.v. + 2 digits)
m.v. - measured value
Document Downloads
Sonel MZC-320S/330S High-Current Fault Loop Impedance Meter Datasheet Datasheet
Sonel MZC-320S/330S High-Current Fault Loop Impedance Meter User Manual Manual/Guide
Additional Information
SKU
MZC-320S
Manufacturer Part Code
MZC-320S

Customer Reviews

 
Sonel MZC-320S High-Current Fault Loop Impedance Meter
£2,530.00
£3,036.00 inc vat
£2,530.00
£3,036.00 inc vat