TSI IAQ-Calc Meters assess and track indoor air quality (IAQ). The 7515 offers an affordable solution for carbon dioxide (CO₂) monitoring. Models 7525 and 7545 measure and log multiple parameters simultaneously. The 7525 captures CO₂, temperature, and humidity while also calculating dew point, wet bulb temperature, and percentage outside air. The 7545 extends these capabilities by including carbon monoxide (CO) detection.
| Feature | 7515 | 7525 | 7545 |
|---|---|---|---|
| CO₂ | + | + | + |
| CO | + | ||
| Temperature | + | + | |
| Humidity | + | + | |
| Percentage outside air | + | + | |
| Dew point | + | + | |
| Wet bulb temperature | + | + | |
| Data logging/downloading | + | + | |
| Statistics | + | + | + |
| Review data | + | + | |
| Certificate of Calibration | + | + | + |
Get a free gift this Black! Even better, this bonus stacks with any other offer.
Free item will automatically add to your basket. Limited Stock. Offer is based on ex VAT basket total after discounts and before shipping costs. See Black Friday Offers for details.
Remember: We will not be beaten on price. Contact us if you've seen a cheaper price.
| 7515 | 7525 | 7545 | |
|---|---|---|---|
| CO₂ Sensor Type | Dual-wavelength NDIR (non-dispersive infrared) | ||
| CO₂ Range | 0 to 5,000 ppm | ||
| CO₂ Accuracy* | ±3.0% of reading or ±50 ppm, whichever is greater | ||
| CO₂ Resolution | 1 ppm | ||
| CO₂ Response Time | 20 seconds | ||
| Temperature Sensor Type | N/A | Thermistor | |
| Temperature Range | 0 to 60°C (32 to 140°F) | ||
| Temperature Accuracy | ±0.5°C (±1.0°F) | ||
| Temperature Resolution | 0.1°C (0.1°F) | ||
| Temperature Response Time | 30 seconds (90% final value, air velocity 2 m/s [400 ft/min]) | ||
| Relative Humidity Sensor Type | N/A | Thin-film capacitive | Thin-film capacitive |
| RH Range | 5% to 95% RH | ||
| RH Accuracy** | ±3.0% RH | ||
| RH Resolution | 0.1% RH | ||
| RH Response Time | 20 seconds (63% final value) | ||
| Percentage Outside Air Range | 0 to 100% | ||
| Percentage Outside Air Resolution | 0.1% | ||
| CO Sensor Type | N/A | Electro-chemical | |
| CO Range | 0 to 500 ppm | ||
| CO Accuracy | ±3.0% of reading or ±3 ppm, whichever is greater | ||
| CO Resolution | 0.1 ppm | ||
| CO Response Time | <60 seconds to 90% step change | ||
| Operating Temperature | 5 to 45°C (40 to 113°F) | ||
| Storage Temperature | -20 to 60°C (-4 to 140°F) | ||
| Logging Capability Ranges | N/A | Logs up to 30,300 data points with key (3) measured parameters enabled | Logs up to 26,900 data points with key (4) measured parameters enabled |
| Time Constant | 1 sec, 5 sec, 10 sec, 20 sec, 30 sec (user selectable) | ||
| Log Intervals | User-selectable: 1 second to 1 hour | ||
| Meter Dimensions | 8.4 cm x 17.8 cm x 4.4 cm (3.3 in. x 7.0 in. x 1.8 in.) | ||
| Probe Dimensions | 7.0 cm length x 1.9 cm diameter (2.75 in. x 0.75 in.) | 17.8 cm length x 1.9 cm diameter (7.0 in. x 0.75 in.) | |
| Weight (with batteries) | 0.27 kg (0.6 lbs) | ||
| Power Requirements | Four AA batteries | Four AA batteries or AC adapter | |