The Aim-TTi EL302P-USB Digital Bench Power Supply is an ergonomic, economical, and easy-to-use programmable, linear PSU with a single channel and an isolated USB interface for remote control. It has a voltage range of 0 to 30V, a current range of 0 to 2A, and a maximum power output of 60W.
The Aim-TTi EL302P-USB Digital Bench Power Supply’s linear regulation ensures excellent line and load regulation, good transient response, and low output noise.
The Aim-TTi EL302P-USB Digital Bench Power Supply’s convection cooling also eliminates fan noise.
The Aim-TTi EL302P-USB Digital Bench Power Supply can be programmed to operate in either Constant Current or Constant Voltage mode with automatic crossover. It features a mode indicator that illuminates when the Aim-TTi EL302P-USB Digital Bench Power Supply is operating in Constant Current mode.
The Aim-TTi EL302P-USB Digital Bench Power Supply’s DC on/off switch allows the user to view preset voltage and current levels before connecting a load.
Voltage and current levels are indicated on the Aim-TTi EL302P-USB Digital Bench Power Supply’s large, backlit display. Voltages are indicated to a resolution of 100mV on the four-digit voltage meter while currents are shown to a resolution of 10mA on the three-digit current meter.
Analogue controls ensure that voltage and current levels can be configured easily, quickly, and precisely. The Aim-TTi EL302P-USB Digital Bench Power Supply includes coarse and fine voltage controls and a logarithmic current control for setting low currents accurately.
Using a simple command set and the Aim-TTi EL302P-USB Digital Bench Power Supply’s isolated USB interface the operator can control the voltage, current, and output activation/ deactivation remotely. The USB interface also provides a readback of metering values and operational status.
The Aim-TTi EL302P-USB Digital Bench Power Supply is a versatile, precise, and reliable programmable PSU with an isolated USB interface.
Get a free gift this Black! Even better, this bonus stacks with any other offer.
Free item will automatically add to your basket. Limited Stock. Offer is based on ex VAT basket total after discounts and before shipping costs. See Black Friday Offers for details.
Remember: We will not be beaten on price. Contact us if you've seen a cheaper price.
| EX-R Model Range | |||
| Voltage/Current Levels | EL301R | 0 to >30V; 0 to >1A | (30W nominal power) |
| EL183R | 0 to >18V; 0 to >3.3A | (60W nominal power) | |
| EL302R | 0 to >30V; 0 to >2A | (60W nominal power) | |
| EL561R | 0 to >56V; 0 to >1.1A | (60W nominal power) | |
| EL155R | 0 to >15V; 0 to >5A | (75W nominal power | |
| EL303R | 0 to >30V; 0 to >3A | (90W nominal power | |
| EL302RD | 2 x (0 to >30V; 0 to >2A) | (120W nominal power | |
| EL302RT | 2 x (0 to >30V; 0 to >2A plus 1.5 to 5.0V @ 2A | (130W nominal power) | |
| EL302P/-USB | 0 to 30V; 0 to 2A | (60W nominal power) | |
| Output Specifications | |||
| Output Setting & Control | Voltage Setting | By coarse and fine controls. | |
| Voltage Setting (EL302P/-USB) | By coarse and fine rotary encoders or RS-232 interface. Resolution 10mV | ||
| Current Setting | By single logarithmic control | ||
| Current Setting (EL305P/-USB) | By single rotary encoder or RS-232 interface. Resolution 10mA | ||
| Output Mode | Constant voltage or constant current with automatic cross-over. CC indicator lit in constant current mode. |
||
| Output Switch | Electronic, non-isolating. Preset voltage and current limit are displayed when the Output is off. On state indicated by LED. | ||
| Output Performance | Ripple & Noise | Typically <1mV rms, (CV mode, 20MHz bandwidth) | |
| Load Regulation | <0·01% of maximum output for a 90% load change (using remote sense). | ||
| Line Regulation | <0·01% of maximum output for 10% line change | ||
| Transient Response | <50µs to within 50mV of setting for a 5% to 95% load change | ||
| Temp. Coefficient | Voltage: typically <100ppm /°C. | ||
| Output Protection | Output will withstand forward voltages of up to 20V above rated output voltage. Reverse protection by diode clamp for currents to 3A. |
||
| Output Connections | Output Terminals | Universal 4mm safety binding posts on 19mm (0·75”) spacing | |
| Note | Terminals can accept fixed shroud 4mm plugs, standard 4mm plugs, fork terminals, and bare wires | ||
| Remote Sense | Sense Selection | Voltage sensing is selected as Local or Remote by the front panel switch. | |
| Sense Terminals | Sprung loaded screw-less terminals | ||
| Meter Specifications | |||
| Display Type | Dual 4-digit meters, 14mm (0·56”) LED | ||
| Display Type (EL302P/-USB) | 4-digit meter for voltage and 3-digit meter for current. | ||
| Voltage Meter | Resolution | 10mV | |
| Resolution (EL302P/-USB) | 100mV | ||
| Accuracy | 0·3% of reading ± 3 digits | ||
| Accuracy (EL302P/-USB) | 0·3% of reading ± 1 digit, | ||
| Current Meter | Resolution | 1mA | |
| Resolution (EL302P/-USB) | 10mA | ||
| Accuracy | 0·5% of reading ± 3 digits | ||
| Accuracy (EL302P/-USB) | 0·6% of reading ± 1 digits | ||
| Note for EL302P/-USB | Note that in constant voltage mode, the meter will show the set voltage to a resolution of 10mV. However, the metering resolution is limited to 100mV when in constant current mode, and the last digit will be set to zero. | ||
| Auxiliary Output (EL302RT only) | |||
| Voltage | Variable <1.5V to >5V by front panel control. | ||
| Meter accuracy | 0.3% ± 4 digits. | ||
| Current limit | 2A minimum | ||
| Load regulation | <3% for 90% load change | ||
| Line regulation | <0.2% for 10% line voltage change | ||
| Ripple & Noise | Typically <5mVrms, <15mVpk-pk (20MHz bandwidth) | ||
| Output Protection | Output will withstand up to 7V forward voltage. Diode clamp reverse protection for currents up to 3A |
||
| Output Terminals | Universal 4mm safety binding posts on 19mm (0·75”) spacing | ||
| Status Indication | UNREG lamp | ||
| General Specifications | |||
| Input | AC Input | 230V AC or 115V AC ± 10%, 50/60Hz. Installation Category II | |
| VA Ratings |
EL301R - 85 VA; EL302R, EL302P, EL183R, EL561R - 160VA; |
||
| Temperature & Environmental | Operating Range | +5ºC to +40ºC, 20% to 80% RH | |
| Storage Range | -40ºC to + 70ºC | ||
| Environmental | Indoor use at altitudes up to 2000m, Pollution Degree 2 | ||
| Cooling | Silent fan-less convection cooling. | ||
| Safety & EMC | Safety | Complies with EN61010-1 | |
| EMC | Complies with EN61326 | ||
| Physical | Size | Single output models - 140x160x320 mm (WxHxD). Dual and triple output models - 260x160x295 mm (WxHxD) |
|
| Weight | EL301R - 3.4kg; EL302R, EL302P, EL183R, EL561R - 4.4kg: EL155R, EL303R - 5.0kg; EL302RD, EL302RT - 7.5kg. |
||
| Voltage Sensing EL302P/-USB | Voltage sensing is local only (i.e. no remote sense) | ||
| Power-down Memory EL320P/-USB | The power supply saves the voltage, current and output-enable status at power down and restores the settings at power up. | ||
| Remote Control EL302P/-USB | Isolation | Fully optoisolated from power supply output. | |
| Remote Functions | Set Voltage, Set Current, Set Output On/Off, Read Voltage, Read Current, Read On/Off, Read Mode (CV or CC). |
||
| Setting Accuracy | Voltage 0.3% ±20mV. Current 0.6% ±20mA. | ||
| Setting Resolution | Voltage 10mV. Current 10mA | ||
| Readback Accuracy | Voltage 0.3% ±100mV. Current 0.6% ±20 mA. | ||
| Readback Resolution | Voltage 100mV. Current 10mA | ||
| RS-232 Interface (EL302P) | Baud Rate | Variable from 600 baud to 9,600 baud | |
| USB Interface (EL302P-USB) | Conformance | USB 2.0. Compatible with USB 1.x. | |