Fluke's 53 II is a single input thermometer that uses thermocouples to carry out extremely accurate measurements of surface temperature in practically any application.
Fluke 50 Series II Digital Contact Thermometers
Made of durable materials and designed to resist the effects of impact, dust and splash damage, this product is suitable for use in everywhere from domestic installations to heavy-duty environments such as industrial areas. It's also easy to use, with simple user interface, large backlit screen and a suite of advanced features which are detailed further below.
As a temperature measurement device the Fluke 53 II is incredibly versatile; it's designed to accept a total of 7 different thermocouples types, ensuring that you always get the measurement you need without relying on other testers. It's compatible with J, K, T, E, R, S and N type thermocouples and depending on which thermocouple is equipped determines the overall measurement range possible on the device.
The 53 II also includes built-in memory which allows the device to be used for continuous measurements. This means users can set their own measurement logging time, leave the meter to calculate measurements and recall the information on the tester once completed. It also comes with a USB port, allowing this digital thermometer to be connected up to a PC to allow for download of testing data into Fluke's FlukeView Forms software package (both sold separately).
Fluke 53 II Single Input Digital Thermometer Key Features
Relative time clock time stamps data
Electronic offset function to negate incorrect thermocouple measurements
Compatible with type J, K, E, T , R, S and N type thermocouples
Single input digital thermometer
Readouts are possible in Celsius, Kelvin or Fahrenheit
Splash, dust and impact resistant casing
User-friendly front panel is easy to operate
Sleep mode to increase overall battery life
Battery door allows easy battery replacement without the need to break the calibration seal
Large backlit screen for viewing the tester in all lighting conditions
Recall functionality
Built in memory (500 data points)
USB connectivity to PC
Full List of Products Included
Fluke 53 II Single Input Digital Thermometer
Impact Absorbing Holster
80-PK-1 Bead Probe Thermocouple
£499.00
£598.80 inc vat
Free Delivery*
Only 1 in Stock:Available Next Working Day*
Important Notice This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
Spend £150+ (Ex VAT) on any qualified Fluke or Beha-Amprobe product(s) and claim a free tool of your choice from the list at Fluke Promotion. Valid February 17 2025 - July 31 2025.
Claims are made direct to Fluke. Terms and conditions apply.
Technical Information
Specification
Fluke 53 II Technical Specifications
Temperature accuracy
Above -100 °C:
J, K, T, E, and N-type: ±[0.05% + 0.3°C]*
R and S-type: ±[0.05% + 0.4°C]*
Below -100 °C:
J, K, E, and N-types: ±[0.20% + 0.3°C]*
T-type: ±[0.50% + 0.3°C]
Temperature
J-type:
-210 °C to 1200 °C
K-type:
-200 °C to 1372 °C
T-type:
-250 °C to 400 °C
E-type:
-150 °C to 1000 °C
N-type:
-200 °C to 1300 °C *
R and S-type:
0 °C to 1767 °C *
Temperature scale
ITS-90
Applicable standards
NIST-175
Display Resolution
0.1 °C, 0.1 K < 1000
1°C, 1 K >=1000
Note
*
Only the Fluke Models 53 II B and 54 II B thermometers are capable of measuring N, R, and S-type thermocouples.
Environmental Specifications
Operating Temperature
-10 °C to 50 °C
Storage Temperature
-40 °C to 60 °C
Humidity (Without Condensation)
0% to 90%; 0 °C to 35 °C
0% to 70%; 0 °C to 50 °C
Safety Specifications
Overvoltage category
CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2