Hanna Instruments HI-3512-02 pH/EC/TDS Bench Meter

All Hanna Instruments Products
  • pH and EC Probes
  • Automatic Temperature Compensation
  • PC interface via USB
  • Log up to 400 samples
SKU
HI-3512-02
MPN
HI-3512-02

Read More

View All pH Meters & Water Quality Testers

The Hanna HI-3512-02 is a 2-channel benchtop meter with calibration warnings and a graphic LCD. It can also log up to 400 samples. Channel-1 has pH/ORP/ISE and temperature measurement capabilities, and channel-2 measures EC/TDS/NaCl/Resistivity and temperature.

Key Features

  • Up to five-point pH calibration with seven standard buffers
  • Up to five-point ISE calibration with six standard solutions
  • 0.001 pH resolution
  • GLP features
  • Automatic Temperature Compensation
  • PC interface via USB
  • Log on demand of up to 400 samples

What's Included?

  • Benchtop meter
  • HI-76310 conductivity/TDS probe
  • HI-1131B pH electrode
  • HI 7662-T temperature probe
  • Starter pack of buffer and cleaning solutions
  • HI-76404N electrode holder
  • 12Vdc adapter
  • Instructions
£558.50
£670.20 inc vat
Free Delivery*
Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
558 Reward Points 60 Days Return

Ask An Expert
Price Match
Technical Information
Specification
pH Range -2.0 to 20.0 pH / -2.00 to 20.00 pH / 2.000 to 20.000 pH
pH Resolution 0.1 pH / 0.01 pH / 0.001 pH
pH Accuracy ±0.01 pH / ±0.002 pH
pH Calibration Up to 5 points / 7 Standard Buffers (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) / 2 Custom buffers
ORP Range ±2000.0 mV
ORP Resolution 0.1 mV
ORP Accuracy ±0.2 mV
ISE Range 1.00x10-7 to 9.99x1010 conc.
ISE Resolution 3 digits 0.01, 0.1, 1, 10 conc.
ISE Accuracy ±0.5% of reading (monovalent ions) / ±1% of reading (divalent ions)
ISE Calibration Up to 5 points / 6 standards (0.1, 1, 10, 100, 1000, 10000 ppm)
Temperature Channel 1 Range -20.0 to 120.0 °C (-4.0 to 248.0 °F)
Temperature Channel 1 Resolution 0.1 °C (0.1 °F)
Temperature Channel 1 Accuracy ±0.2 °C (±0.4 °F) (excluding probe error)
Rel mV offset range ±2000 mV
Slope calibration From 80 to 110%
pH Temperature Compensation Manual / Automatic
Electrode Hanna BNC connection pH / ORP / ISE electrodes
Temperature Probe RCA connection / Recommended option
EC Range 0 to 400 mS/cm (shows values up to 1000 mS/cm) / Actual conductivity 1000 mS/cm
0.001 to 9.999 μS/cm
10.00 to 99.99 μS/cm
100.0 to 999.9 μS/cm
1.000 to 9.999 mS/cm
10.00 to 99.99 mS/cm
100.0 to 999.9 mS/cm
1000 mS/cm (autoranging)
EC Resolution 0.001 μS/cm
0.01 μS/cm
0.1 μS/cm
0.001 mS/cm
0.01 mS/cm
0.1 mS/cm
1 mS/cm
EC Accuracy ±1% of reading (±0.01 µS/cm or 1 digit, whichever is greater) excluding probe error
EC Calibration Up to 2 points / 7 Standards (0.00 µS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 111.8 mS/cm)
Resistivity Resolution 1.0 to 99.9 ohms
100 to 999 ohms
1.00 to 9.99 Kohms
10.0 to 99.9 Kohms
100 to 999 Kohms
1.00 to 9.99 Mohms
10.0 to 100.0 Mohms (autoranging)
Resistivity Accuracy 0.1 ohm
1 ohm
0.01 Kohms
0.1 Kohms
1 Kohms
0.01 Mohms
0.1 Mohms
Resistivity Calibration ±1% of reading (±10 ohms or 1 digit, whichever is greater) excluding probe error
TDS Range 0.000 to 9.999 ppm
10.00 to 99.99 ppm
100.0 to 999.9 ppm
1.000 to 9.999 g/L
10.00 to 99.99 g/L
100.0 to 400.0 g/L (autoranging)
TDS Resolution 0.001 ppm, 0.01 ppm, 0.1 ppm, / 0.001 g/L, 0.01 g/L, 0.1 g/L
TDS Accuracy ±1% of reading (±0.05 ppm or 1 digit, whichever is greater) excluding probe error
TDS Factor 0.40 to 1.00
Salinity Range % NaCl: 0.0 to 400.0 %
Salinity Resolution 0.1%
Salinity Accuracy ±1% of reading (excluding probe error)
Temperature Channel 2 Range -20.0 to 120.0 °C (-4.0 to 248.0 °F)
Temperature Channel 2 Resolution 0.1 °C (0.1 °F)
Temperature Channel 2 Accuracy ±0.2 °C (±0.4 °F) (excluding probe error)
NaCl Calibration Max. 1 point only (with HI7073 standard)
EC probe DIN connection / Recommended option
Temperature Source Automatic / Manual
EC Temperature Compensation NoTC, MTC, ATC
Reference temperature 15, 20, 25 °C
Log on demand 400 samples
Lot logging 5, 10, 30 seconds / 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes, AutoEnd (maximum 600 samples)
Environment 0 to 50 °C (32 to 122 °F) / max. RH 55% non-condensing
Power Supply 12 Vdc power adapter
PC Interface opto-isolated USB
Dimensions 235 x 207 x 110 mm (9.2 x 8.14 x 4.33 in.)
Weight 1.8 Kg (4.1 lbs)
Document Downloads
Hanna Instruments HI-3512-02 pH/EC/TDS Bench Meter User Manual Manual/Guide
Additional Information
SKU
HI-3512-02
Manufacturer Part Code
HI-3512-02

Customer Reviews

 
Hanna Instruments HI-3512-02 pH/EC/TDS Bench Meter
£558.50
£670.20 inc vat
£558.50