The MI 3290 Earth Analyser is available in multiple sets which are a combination of different accessories and measurement functions, please note some functions may only work if you have relevant accessory, please refer to the set specifications below. The functionality of an existing set can be expanded by ordering additional accessory and license keys.
Metrel MI3290 GF - Licence key for Grounding and voltage Funnel functionality of Earth Analyser.
Metrel MI 3290 GL - Licence key for Grounding and Lightning functionality of Earth Analyser.
Metrel MI 3290 GP - Licence key for Grounding of Pylons functionality of Earth Analyser.
Metrel MI 3290 GX – Licence key for all of the above.
Metrel’s MI3290 Earth Analyser is designed for diagnosing:
And is capable of performing the following functions:
The MI 3290 GX licence key includes the capability for all measurement modes:
The MI 3290 Earth Analyser is a multi-function device capable of carrying out various tests and diagnostics in earth analysis. It is mains or battery powered and built inside an IP65 rated case (IP54 when open) and is suited to those with experience in the field, the tester itself is simple to use, with a 4.3” colour touch screen, easy to read results and intuitive menu system, the tester can be used without the need for any special training. The screen provides the user with helpful message field warnings such as test information and warnings, battery level indication, a virtual keyboard, various indication messages and limits parameter indications which can be accompanied by a beep to warn the user.
Help menus are available which provide the user with diagrams illustrating the proper connection of the instrument to the unit that requires testing.
The user can customise test sequences which can be easily accessed from the main screen for quicker procedures. Autotests can be pre-programmed on PC with the Metrel ES Manager software and uploaded to the MI 3290 Earth Analyser.
Test results can be stored on internal memory and evaluated and archived at a later date on the PC software. The Metrel ES Manager software which is included is for measurement pre and post-processing: preparation of the test structure, result download, tree-view, table view and graphical view, storing and printing.
High electrical noise immunity makes this instrument best suited for an industrial environment but not limited to. Other applications can include:
The GX4 Set also includes:
Get a free gift this Black Friday! Even better, this bonus stacks with any other offer.
Free item will automatically add to your basket. Limited Stock. Offer is based on ex VAT basket total after discounts and before shipping costs. See Black Friday Offers for details.
| Method | Additional info | Measurement range | Uncertainty |
| Earth resistance 2, 3, 4 -pole | Open-terminal test voltage 20 or 40 VAC | ||
| Short-circuit test current > 220 mA | |||
| Test Frequency | |||
| 55 Hz…329 Hz | 0.010 Ω … 19.99 kΩ | ±(3 % of reading + 3 digits) | |
| 659 Hz … 2.63 kHz | 0.00 Ω … 1.999 kΩ | ±(5 % of reading + 3 digits) | |
| 3.29 kHz … 15 kHz | 0.00 Ω … 199.9 Ω | ±(8 % of reading + 3 digits) | |
| Selective earth resistance with iron clamp | Open-terminal test voltage 40 VAC | ||
| Short-circuit test current > 220 mA | |||
| Test Frequency | |||
| 55 Hz … 329 Hz | 0.010 Ω … 19.99 kΩ | ±(8 % of reading + 3 digits) | |
| 659 Hz … 1.50 kHz | 0.00 Ω … 1.999 kΩ | ||
| Selective earth resistance of pylons with flex clamp | Open-terminal test voltage 40 VAC | ||
| Short-circuit test current > 220 mA | |||
| Test Frequency | |||
| 55 Hz…329 Hz | 0.010 Ω … 19.99 kΩ | ±(8 % of reading + 3 digits) | |
| 659 Hz … 1.50 kHz | 0.00 Ω … 1.999 kΩ | ||
| Passive mode | 0.00 Ω … 19.99 kΩ | ||
| Earth resistance with two iron clamps | Test Frequency | 0.00 Ω … 9.99 Ω | ±(5% of reading + 2 digits) |
| 82 Hz ... 329 Hz | 10.0 Ω … 49.9 Ω | ±(10 % of reading + 2 digits) | |
| 50.0 Ω … 100 Ω | ±(20 % of reading) | ||
| Specific earth resistance ro Wenner and Schlumberger method | Open-terminal test voltage 20 or 40 V AC | 0.00 Ωm … 19.99 kΩm | calculated value (consider the uncertainty of 4 – pole measurement) |
| Short-circuit test current >220 mA | |||
| Test frequency 164 Hz | |||
| Earth Potential | Open-terminal test voltage 40 V AC | 0.0 mV … 49.99 V | calculated value (consider uncertainty of 3 – pole measurement) |
| Short-circuit test current >220 mA | |||
| Test frequency 55 ÷ 329 Hz | |||
| HF-Earth Resistance 3 pole | Open-terminal test voltage 40 VAC | 0.00 Ω … 19.9 Ω | ±(3 % of reading + 2 digits) |
| Short-circuit test current >40 mA | 20.0 Ω … 299 Ω | ||
| Test frequency 25.000 Hz | |||
| Impulse Earth Resistance | Open-terminal test voltage ~120 V peak | 0.0 Ω … 199 Ω | ±(8 % of reading + 8 digits) |
| Short-circuit test current ~6 A peak | |||
| Impulse waveform 10 / 350 µs | |||
| DC Resistance RLOW | Test current 200 mA | 0.00 Ω … 1.99 kΩ | ±(2 % of reading + 2 digits) |
| DC Resistance CONT | Test current 7 mA | 0.00 Ω … 19.9 kΩ | ±(3 % of reading + 2 digits) |
| AC Impedance | Test frequency 55 Hz … 15 kHz | 0.00 Ω … 19.99 kΩ | ±(3 % of reading + 2 digits) |
| Current RMS (Iron Clamp) | Nominal frequency 45 Hz …1.5 kHz | 1.0 mA …7.99 A | ±(2 % of reading + 3 digits) |
| Current RMS (Flex Clamp) | Nominal frequency 45 Hz …1.5 kHz | 10 mA … 49.9 A | ±(8 % of reading + 3 digits) |
| Battery power supply | 14.4 V DC (4.4 Ah Li-ion) | ||
| Mains power supply | 90-260 VAC, 45-65 Hz, 100 VA (300 V CAT II) | ||
| Degree of protection |
IP 65 (case closed) IP 54 (case open) |
||
| Dimensions (w x h x d) | 36 x 16 x 33 cm | ||
| Display | 3.4'' colour LCD display with backlight and touch screen | ||
| Communication | USB, BT | ||
| Memory | >1GB | ||
| Licence key | GX | GL | GF | GP |
| Measurement methods | ||||
| Ground Z 2-pole | • | • | • | • |
| Ground Z 3-pole | • | • | • | • |
| Ground Z 4-pole | • | • | • | • |
| Single/multi/sweep frequency | • | • | • | • |
| Wenner 4-pole | • | • | • | • |
| Schlumberger 4-pole | • | • | • | • |
| Selective (iron clamp) | • | • | ||
| Stakeless 2-clamps | • | • | ||
| Transient Impulse Impedance | • | • | ||
| HF 25 kHz Impedance | • | • | ||
| Step / Touch | • | • | ||
| Voltage potential | • | • | ||
| Low Impedance 4-point | • | • | ||
| Low Resistance 200 mA | • | • | ||
| Tower Passive one rod / Flex clamps | • | • | ||
| Tower FOP / 1xFlex clamp | GX1 | • | ||
| Tower FOP / 4xFlex clamp | GX4 | Option | ||
| Mono Tower FOP / Flex clamp | • | • | ||
| Measurement accessory | ||||
| Current earth spike, 90 cm, 2 pcs Potential earth spike, 50 cm 2 pcs G clamp Shielded test lead on reel, 75 m Test lead on reel 50 m, 3 pcs (black, green, blue) Test lead, 5 m, 2 pcs (blue, red) Set of test probes, crocodile clip and 2 m test lead, 4 pcs |
• | • | • | • |
| Flex clamp 5 m with 15 m shielded cable |
4 pcs (GX4) |
1 pce | ||
| Iron clamp, 2 pcs | • | • | ||
| Kelvin clamp with 2,5 m cable, 2 pcs | • | • | ||
| Step Contact Meter Measuring Set | • | • | ||