Get a TPI 709R combustion flue gas analyser, all standard accessories and a bundle pack with IR printer, smoke pump and oil filter for one great low price!
The TPI 709R is a low cost, easy-to-use and highly accurate combustion analyser compatible with combustion boilers powered by natural gas, LPG, light oil, heavy oil, bituminous coal, anthracite coal, coke, butane, wood and bagasse.
Featuring a built-in manometer for pressure measurements and dual type-K temperature inputs, this analyser can also measure combustion efficiency, CO, O2, flue temperature and more.
The analyser has a pump driven sensor to ensure fast response, a large-size LCD display and built-in memory for storage of up to 99 testing records.
This kit also comes with:
Please note that our 14-day money-back guarantee for flue gas analysers only applies if the tester is found to be faulty.
Get more from your TPI 709R with these great value kits!

Free TPI Spare Filter Pack with TPI Flue Gas Analysers
Purchase a TPI Flue Gas Analyser and receive a spare filter pack containing 1 x A796-D disc filter & 5pk of A796-F particle filters.
Get a free gift this Black! Even better, this bonus stacks with any other offer.
Free item will automatically add to your basket. Limited Stock. Offer is based on ex VAT basket total after discounts and before shipping costs. See Black Friday Offers for details.
Remember: We will not be beaten on price. Contact us if you've seen a cheaper price.
| Carbon Monoxide (CO) Measurement |
Range 0 to 10,000 ppm Resolution 1 ppm Accuracy +/-5ppm or 5% of reading whichever is greater |
| Oxygen (02) Measurement | Range 0 to 25% Resolution 0.1% Accuracy ±0.3% |
| Carbon Dioxide (CO2) | Range 0 to 25% Resolution 0.1% Calculated Value |
| Nitric Oxide Measurement | N/A |
| NOX Measurement | N/A |
| Temperature Measurement | Range -40 to 1472°F, or -40 to 800°C Resolution 1°F or °C Accuracy (K-type) ±0.3%, ±2°F or ±1°C |
| Draft/Pressure Measurement |
Selectable Ranges mBar,kPa, and inH2O Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60 inH2O to +60 in H20 Resolution 0.001 inH2O Accuracy ±0/5% fsd |
| Gross/Net Efficiency | Range 0 to 100% Resolution 0.1% Calculated Value |
| CO/CO2 Ratio | Range 0 to 0.999 Resolution 0.001 Calculated Value |
| Operating Temperature | 14°F to 122°F (-10°C to 50°C) |
| Battery Type | Rechargeable Batteries |
| Selectable Fuels | Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse |
| Display Type | Backlit 3 line LCD |
| Data Storage | 50 Locations |
| Data Logging | N/A |
| Print Capability | Yes, via optional IR printer (A740) |
| PC Communication | N/A |
| Date and Time Function | 24 Hour Real Time Clock |
| Dimensions | 200mm x 90mm x 60mm |
| Weight | 500g |
| Conformity | BS7927 (and the draft BS7967) |