All C.Scope Products

C.Scope SGV4 Dual-Frequency Datalogging Signal Generator – 33kHz & 131kHz

SKU
SGV4-D
Rating:
0%
(0)
Reward Points
:
595
£714.00 £595.00
Free UK Delivery*
Advice & Support
Price Match Request
C.Scope SGV4 Dual-Frequency Datalogging Signal Generator facing right

The C.Scope SGV4 Dual-Frequency Datalogging Signal Generator is a signal transmitter designed to be used alongside C.Scope’s CXL4 and DXL4 Cable Avoidance Tools. It can be used to maximise the number of buried utilities that are energised and therefore detected, including street lighting cables.

In addition to issuing a dual-frequency signal output, the C.Scope Dual-Frequency Datalogging Signal Generator supports three signal application techniques (Direct Connection, Wraparound and Induction). It is also equipped with datalogging capabilities, an automatic daily self-test and a high-resolution backlit display.

Simultaneous Dual-Frequency Signal Output

The C.Scope SGV4 Dual-Frequency Datalogging Signal Generator will simultaneously issue a 33kHz and 131kHz signal output. This increases the number of buried pipes, cables and services that will be energised and subsequently detected.

To improve detection of cables with a smaller diameter or cables that are poorly earthed, the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator’s dual-frequency output signal can be applied using the Induction method or via a signal clamp.

Signal Application Techniques

To enable maximum energisation and subsequent detection, the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator supports the following three signal application techniques:

Direct Connection

The Direct Connection method is most effective when using the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator with a signal clamp, signal injectors or direct connection cables. The Direct Connection technique is ideal for identifying, tracing and measuring the depth of individual pipes and cables.

Wraparound

When it is difficult or inconvenient to use the Direct Connection method, the Wraparound technique can be used to energise street or car park lighting cables.

Induction

The C.Scope SGV4 Dual-Frequency Datalogging Signal Generator induces a signal to enable energisation and subsequent detection of previously unknown, undetected or inaccessible underground metal pipes or cables.

Pulsed or Continuous Signal Output

Signals can be applied continuously or as a pulse. When issuing a signal, the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator sounds an audible output. The audible output can be switched off using the audio mute control.

The user can switch from Pulse mode to Continuous mode at the push of a button.

High Power Signal

The C.Scope SGV4 Dual-Frequency Datalogging Signal Generator features a fully adjustable one watt power output enabling deeper and less conductive pipes and cables to be energised and traced over long distances.

In addition to this, the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator features a four-position power level adjustment allowing the user to control the power application.

Data Logging

A year’s worth of data can be recorded on the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator and its corresponding C.Scope CXL4 or DXL4 CAT. Saved data can be transferred to a PC via a USB.

Automatic Daily Self-Test (ADST)

Upon start-up, the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator will perform a comprehensive Automatic Daily Self-Test. A positive result confirms that the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator is working to its specifications.

Test results are saved to the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator's onboard memory and can be downloaded to a PC within twelve months. Using C.Scope’s PC Toolkit, the user can create a Product Validation Certificate using these test results. The C.Scope PC Toolkit can also be used to view the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator’s original calibration certificate. As the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator performs an automatic daily self-test, it does not require periodic calibration.

High-Resolution Backlit Digital Display

The Automatic Daily Self-Test results are displayed on the C.Scope SGC4 Genny's large, easy-to-read backlit LCD. This display is mounted behind a protective polycarbonate lens.

In addition to showing the ADST result, the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator will also indicate the selected function, the power level, the connection quality and the battery condition on its high-resolution display.

Ergonomic, Robust and Durable

The C.Scope SGV4 Dual-Frequency Datalogging Signal Generator features twin-wall construction ensuring that it is robust, durable and has an IP65 ingress protection rating.

Furthermore, the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator features a detachable base that functions as a large accessory tray capable of holding an instruction manual and the standard accessories supplied with this unit (see ‘What’s Included?’) as well as OPTIONAL additional accessories such as signal clamps, sondes and signal injectors.

Finally, the C.Scope SGV4 Dual-Frequency Datalogging Signal Generator is Network Rail approved; it is a versatile, reliable and durable Genny optimised for use with C.Scope’s CXL4 and DXL4 CATs.

C.Scope SGV4 Dual-Frequency Datalogging Signal Generator Key Features

  • A signal transmitter designed to be used alongside C.Scope’s CXL4 and DXL4 Cable Avoidance Tools
  • Maximises the number buried utilities that are energised and therefore detectable
  • Can be used to find and trace street lighting cables
  • Simultaneous dual-frequency signal output: 33kHz and 131kHz
  • Supports three signal application techniques: Direct Connection, Wraparound and Induction
  • Pulsed and Continuous Signal Output modes
  • Switch from Continuous Signal Output mode to Pulsed Signal Output mode at the push of a button
  • Issues an audible output when providing a signal
  • Switch off the audible output using the audio mute control
  • Fully adjustable one-watt power output
  • Adjustable power allows deeper and less conductive pipes and cables to be energised over long distances
  • Four-position power level adjustment allows the user to control the power application
  • Datalogging capabilities
  • Save up to a year’s worth of data on the Genny and corresponding CAT
  • Transfer saved data to a PC via USB
  • Performs an Automatic Daily Self-Test (ADST) upon start-up
  • Saves the ADST results to the onboard memory
  • Download ADST results to a PC within twelve months
  • Create a Product Validation Certificate using the ADST results and C. Scope PC Toolkit
  • Use the C.Scope PC Toolkit to view the Genny’s original calibration certificate
  • Does not require periodic calibration
  • Large, easy-to-read, high-resolution LCD
  • The display is mounted behind a protective polycarbonate lens
  • View the ADST result, selected function, power level, connection quality and battery condition on the display
  • Twin-wall construction
  • Robust and durable
  • IP65
  • Detachable base that functions as a large accessory tray
  • Network Rail approved
  • A versatile, reliable and durable Genny optimised for use with C.Scope’s CXL4 and DXL4 CATs

What’s Included?

  • C.Scope SGV4 Dual-Frequency Datalogging Signal Generator – 33kHz & 131kHz
  • Direct Connection Leads
  • Earth Stake
  • Connection Magnets
  • 10m Auxiliary Earth Lead

C.Scope SGV4 Dual-Frequency Datalogging Signal Generator Technical Specifications 

Controls
All operation is by push-button control as follows



On/Off
Power Level: 4 available power levels via Increase and Decrease Power buttons
Pulse/Continuous Output: toggles between pulse or continuous output using one push button
Audio Output: toggles between loud, muted and silent audio output using one push button
Audio Indications




Audio Feedback on button push
Audio pitch drops with increasing load current in Connected Mode
Audio pitch changes with power level in Induced Mode
Audio output pulses to indicate Pulsed Mode
Low battery indicated by interrupted Audio and output signal
Visual Indication
Multi-segment Liquid Crystal Display indicating:
 
 
 
Output Frequency
Pulse Mode
Pulse Mode
Continuous Mode

Battery Condition

Output Level (bargraph)
Speaker Mute
Self Test Result
Data Connector Standard USB Mini B connector. USB 2.0 Compatible
Self Test Automatic Daily Self Test and manual Self Test function
Output Induced = 131,072Hz and 32,768Hz
Connected = 131,072Hz and 32,768Hz
Carrier Pulse Frequency: 7.5Hz (pulsed mode)
Connected Mode Connection Mode automatically selected when lead is plugged into socket
Maximum Output Voltage (open circuit): 28V rms
Maximum Output Current (short circuit): 65mA rms
Maximum Power: 1W into 400Ω load
Construction Case moulded from high impact plastic
Designed to withstand 1m (3’3”) drop onto a hard surface
Incorporates clip on accessory storage compartment
Weight (including batteries, Connection Leads and Earth Stake 3.4kg (7 lb 7 oz)
Dimensions (with Accessory Tray fitted) 360mm x 180mm x 230mm (14.1” x 7” x 9”)
Battery Type Internal 4 x ‘D’ (LR20) cells (either alkaline non-rechargeable or NiMH rechargeable)
Battery Life up to 40 hours intermittent use at 20ºC (68ºF) using alkaline cells
IP Rating 65
Notes 

Network Rail Approved
Performance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Signal Generators are in compliance with the essential requirements and other relevant provisions of Council Directive 2014/53/EU (EMC). Compliance has been demonstrated by testing representative samples to the harmonised standards EN300-330 and EN301-489. The essential radio test suites have been carried out and the equipment is in conformity with all applicable directives. All C.Scope Signal Generators comply with the essential requirements and other provisions of Council Directive 2011/65/EU (RoHS).
One Watt Power Yes
Power Levels 4
Generator / Transmitter Frequencies: 33+131kHz (Connected and Induced) Yes
Pulsed / Continuous Output Signal Yes
Signal Connection Mode: Direct Connection Yes
Signal Connection Mode: Wraparound Yes
Signal Connection Mode: Induction Yes
Automatic Daily Self Test Yes
Data Logging Yes
Data Transfer via USB Yes
High Resolution Backlit Liquid Crystal Display Yes
No Periodic Calibration* Yes
Three Year Warranty** from C.Scope Yes
Batteries*** 4 x D (LR20) Alkaline or NiMH Rechargeable Yes
In-Built Accessory Tray**** Yes
IP65 Yes
Notes 



No Periodic Calibration. The SGV4 does not require periodic recalibration. A Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.
** Three Year warranty. Conditions apply.
*** Batteries. 4 x D LR20 Alkaline or NiMH Rechargeable batteries housed in a secure battery compartment.
**** In-Built Accessory Tray includes Direct Connection Lead, Auxiliary 10m Earth Lead, Connection Magnets, Earth Stake and Instruction Manual
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:C.Scope SGV4 Dual-Frequency Datalogging Signal Generator – 33kHz & 131kHz
Your Rating
Additional Information
SKU SGV4-D
Manufacturer Part Code SGV4-D
International Enquiry