All Comark Products

Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger

SKU
RF312GLYCOL
Rating:
0%
(0)
Reward Points
:
260
£312.00 £260.00
Free UK Delivery*
Advice & Support
Price Match Request
Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger

The Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger can be used to monitor temperatures of perishable items such as food samples, vaccines and medications.

This instrument is equipped with a removable, high-accuracy glycol buffer probe and can measure temperatures between -15°C and +80°C to an accuracy of ±0.2°C (+5°F to +176°F to an accuracy of ±0.4°F). The glycol probe provides a buffered response to changes in temperature thereby simulating the thermal lag experienced by the perishable goods stored in the monitored environment. Additionally, this probe can also be used with Comark’s RF312DUALPLUS High Accuracy Wi-FI Data Logger.

Readings acquired by the Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger can be sent wirelessly to the user’s PC (Comark’s free PC software is required) or to the Comark Cloud (this is a chargeable service). Data sent to the Comark Cloud can be accessed from a variety of locations. Measurements sent to both the user’s PC and the Comark Cloud can be organised into graphs and tables, as well as exported in various formats. It is also possible to view and export historical data using either of these data storage locations.

Comark’s free PC software is used to set up the Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger; during this configuration process, the user is able to specify which location he/she would like data to be transmitted. The operator is also able to specify sample rates, measurement units (°C or °F) and high and low alarm levels. Furthermore, he/she can issue the logger with a name, ensuring that data is easier to organise.

Once initially configured the Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger does not need to be reconnected to a PC in order to update its settings. Moreover, during initial configuration, the Comark RF312Glycol Diligence Data Logger will establish a connection with the specified/ surrounding Wi-Fi network. Once connected the data logger may be placed anywhere within the Wi-Fi network’s range.

Should this Wi-Fi connection falter the Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger will continue to record readings (for a maximum of thirty days at ten-second sample intervals) until a connection with the PC software or Comark Cloud is re-established. The Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger’s Wi-Fi range can be lengthened using OPTIONAL Wi-Fi extenders.

In addition to this, readings may be viewed via the Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger’s large, two-line, surround LCD. Via this display the user may also view the minimum and maximum temperature readings, alarm indicators; the remaining battery power, indicated via a segmented battery indicator; the Wi-Fi connection and signal strength.

With regards to its practicality, this instrument is supplied with an internal rechargeable lithium polymer battery, however, it can also be powered using an RF320 USB Power Supply (NOT included), allowing the user to tailor the instrument to the test environment.

Adding to this instrument’s adaptability is the glycol probe’s detachable magnetic base and supplied wall bracket. These accessories facilitate the user’s ability to adjust the Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger, ensuring that it is easy to install in a variety of environments.

Finally, the Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger has an IP rating of 43 and the glycol probe includes an IP rating of 67. It is also IEEE 802.11 b/g/n compliant and supports WEP, WPA/WPA2 encryption and enterprise networks.

The Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger is a versatile, adaptable and reliable temperature measurement and data logging instrument.

Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger Key Features

  • Monitor temperatures of perishable items such as food samples, vaccines and medications
  • Equipped with a removable high-accuracy glycol buffer probe
  • Temperature range: -15°C to +80°C / +5°F to +176°F
  • Accuracy: ±0.2°C / ±0.4°C
  • Provides a buffered response to changes in temperature, mimicking the thermal lag experienced by the perishable goods stored in the monitored environment
  • Glycol probe can be used with Comark’s RF312DUALPLUS High Accuracy Wi-FI Data Logger.
  • Readings can be sent to the user’s PC or the Comark Cloud (the Comark Cloud is a chargeable service)
  • Data sent to the Comark Cloud can be accessed from a variety of locations
  • Organise data into graphs and tables
  • Export data in various formats
  • View and export historical data
  • Use Comark’s free PC software to configure the data logger
  • Data storage location can be specified during configuration
  • Configure sample rates, measurement units (°C or °F), high and low alarm levels
  • Assign the logger a name
  • Once initially configured the data logger does not need to be re-connected to alter its settings
  • During initial configuration, the data logger will establish a connection with a Wi-Fi network
  • Once connected the data logger can be placed anywhere within the Wi-Fi network’s range
  • Continues to record measurements even if the Wi-Fi connection is lost
  • Logs measurements until a connection with the Cloud or PC software is re-established (max 30 days at a 10-second sample rate)
  • Lengthen the data logger’s Wi-Fi range using OPTIONAL Wi-Fi extenders
  • Large, two-line, surround LCD
  • View min and max temperature readings
  • Alarm indicators
  • Segmented battery power indicator
  • View Wi-Fi connection and signal strength
  • Internal, rechargeable, lithium polymer battery
  • Can be powered using an RF320 USB Power Supply (NOT included)
  • Glycol probe features a detachable magnetic base
  • Supplied with a wall bracket
  • Data logger: IP43
  • Glycol probe: IP67
  • IEEE 802.11 b/g/n compliant
  • Supports WEP, WPA/WPA2 encryption and enterprise networks
  • A versatile, adaptable and reliable temperature measurement and data logging instrument

What’s Included?

  • Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger
  • Wall Bracket
  • Micro-USB Lead
  • 3m Glycol Buffer Probe
  • 1-Year Warranty From Comark

Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger Technical Specifications

Sensor Type High Accuracy ‘PLUS’ Specification Thermistor
Battery Life >6* Months
USB Supply Voltage 4.5 to 5.5 Vdc
Operating Temperature Range -20°C to +60°C / -4°F to +140°F
Logging Period (User Configurable) 10 Seconds to 12 Hours (Typical 10 Minutes)
Transmission Period (User Configurable) 1 minute to 24 hours (Typical 1 Hour)
Temperature Measurement Range -40 to +125°C / -40°F to +257°F
Temperature Measurement Resolution 0.01°C / 0.01°F
Temperature Display Resolution 0.01°C / 0.01°F
System Temperature Accuracy (-15 to +80°C) ±0.2°C
System Temperature Accuracy (+5°F and +176°F) ±0.4°F
System Temperature Accuracy (-40 to +125°C) ±0.6°C
System Temperature Accuracy (-40°F to +257°F) ±1°F
Logger Dimensions Height 82mm / 3.23" x Width 70mm / 2.75" x Depth 22mm / 0.86"
Supplied Glycol Buffer Probe Lead Length 3m
WiFi Compliance IEEE 802.11b/g/n compliant, supports WEP, WPA/WPA2 encryption and enterprise networks (MS-CHAPv2, PEAP, EAP-FAST, EAP-TTLS)
Glycol Buffer Response Time (t90*) 40 minutes
Notes *The t90 response is the time taken for the temperature probe to achieve 90% of the ambient temperature, after being subjected to an instant change. This response time is designed to reproduce the thermal characteristics of a vaccine vial, accurately tracking the temperature of the vaccine.
Warranty 1- Year Warranty from Comark
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Comark RF312Glycol Diligence Wi-Fi Glycol Simulant Data Logger
Your Rating
Additional Information
SKU RF312GLYCOL
Manufacturer Part Code 4808972
International Enquiry