The Martindale HPAT650 PAT Essentials Kit is for real-world use, making appliance testing quick, accurate, and easy to track. The HPAT650 onboard memory is capable of storing up to 100 test records and can recall results on-screen.
The tester delivers single and sequenced test modes, adjustable pass limits, and a substitute leakage test. The HPAT650 supports Class I, Class II, and IEC lead testing. It has selectable insulation voltages of 250 V and 500 V, a safe 200 mA earth continuity test, a high-resolution colour screen, a simple PASS/FAIL display, and optional help screens. Additionally, it includes USB-C charging with fast charge support.
This Essentials Kit also includes a full complement of accessories: adaptors for all common IEC plug types, an earth bond probe, a microwave leakage detector, a UK socket tester, and a carbonless appliance register booklet. It comes housed in a large, rugged carry case with over 1,000 labels, an insulated screwdriver set, and online PAT training access.
Go pro with the Professional Kit — includes Simply Pats software.
Get a free gift this Black! Even better, this bonus stacks with any other offer.
Free item will automatically add to your basket. Limited Stock. Offer is based on ex VAT basket total after discounts and before shipping costs. See Black Friday Offers for details.
Remember: We will not be beaten on price. Contact us if you've seen a cheaper price.
| Earth Continuity | |
|---|---|
| Test Voltage | >4V DC (into open circuit) |
| Test Current | >200mA DC (into short circuit) |
| Range | 0.01 - 20Ω |
| Resolution | 0.01Ω |
| Accuracy | ± (5% of reading + 2 digits) |
| Fixed / Default Pass Limits | Default ≤0.1, user settable ≤0.5Ω selectable pass for long cable |
| User-Settable Limits | ≤0.1Ω to ≤0.9Ω in 0.1Ω steps |
| Insulation | |
| Test Voltage | User selectable >250V DC at 1mA / >500V DC at 1mA (<312.5V DC open circuit / <625V DC open circuit) |
| User Selectable Voltage | |
| Test Current | <2mA (into short circuit) |
| Range | 0.01MΩ - 100MΩ |
| Resolution | 0.01MΩ (10kΩ - 2MΩ) 0.1MΩ (2MΩ - 20MΩ) 1MΩ (20MΩ - 100MΩ) |
| Accuracy | 5% reading + 2 digits |
| Pass Level | Lead: ≥ 1.0MΩ Class I: ≥1.0MΩ Class II: ≥2.0MΩ |
| User-settable Pass Level | ≥0.3MΩ to ≥ 1MΩ in 0.1MΩ steps ≥1MΩ to ≥ 10MΩ in 1MΩ steps |
| Substitute Leakage Test | |
| Test Voltage | <50V AC (into open circuit) 0.02-20mA DC (into short circuit) |
| Accuracy | ± (5% reading + 2 digits) |
| Pass Level | <5mA |
| Memory | |
| Test Records | 100 tests stored for on-screen recall |
| Power | |
| Batteries | 3.7V 5000mAh lithium polymer battery (non-user replaceable) |
| Battery Life | Fully charged, minimum 1700 complete tests, approx. |
| Auto Power Down | Auto dimming after 3 minutes, Auto power down after 5 minutes of inactivity |
| Environmental | |
| Location | Suitable for indoor and outdoor use in dry weather conditions only |
| Altitude | Up to 2000m |
| Operating Temperature | 0°C to 40°C |
| Humidity | ≤80% RH up to 31°C, decreasing linearly to 50°C RH at 40°C |
| Ingress Protection Class | IP20 |
| Pollution Degree | 2 |
| General | |
| Overload Protection | 300V AC/DC |
| Protection Class | IP20 |
| Safety | Complies with BS EN 61010-1 |