The C.Scope MXT4 Multi-Frequency Datalogging Signal Generator is a signal transmitter designed to be used with C.Scope’s MXL4 Datalogging Precision Cable Locators to identify, pinpoint and trace a wide variety of pipes and cables.

Multi-Frequency

The C.Scope MXT4 Multi-Frequency Datalogging Signal Generator can issue frequency signals ranging from 512/640Hz to 131kHz and supports a dual-frequency 33kHz and 131kHz signal output. The C.Scope MXT4 Multi-Frequency Datalogging Signal Generator enables maximum energisation and detection (using a compatible MXL4 Locator) of buried utilities, pipes and cables. It also improves long-distance tracing and utility identification in congested sites.

Signal Application Techniques

Also contributing to the flexibility of the C.Scope MXT4 Multi-Frequency Datalogging Signal Generator is its ability to support multiple signal application techniques.

Direct Connection

The C.Scope MXT4 Multi-Frequency Datalogging Signal Generator’s Direct Connection technique is most effective when used with a signal clamp, signal injectors or direct connection leads. It enables specific pipes and cables to be identified and traced, and can be used to measure the depths of these utilities. It is especially useful for identifying and tracing poorly earthed cables or cables with small diameters.

Wraparound

The Wraparound technique can be used when it is difficult or inconvenient to use the Direct Connection technique. It is ideal for energising street and car park lighting cables.

Induction

The Induction technique can be used to induce a traceable signal in previously unknown, undetected or inaccessible metal pipes and cables.

High Power Signal

Enabling deeper pipes and cables to be energised and traced over longer distances is the C.Scope MXT4 Multi-Frequency Datalogging Signal Generator’s fully adjustable one-watt power output.

The C.Scope MXT4 Multi-Frequency Datalogging Signal Generator includes a four-position power level adjustment granting the user full control over when and how much power is used.

Pulsed & Continuous Signal Output Modes

The C.Scope MXT4 Multi-Frequency Datalogging Signal Generator is able to issue outputs as a continuous signal or as a pulse signal. The user can switch between Pulse and Continuous Signal Output modes at the push of a button. Pulse Signal Output mode is particularly useful when tracing utilities in high interference situations.

The C.Scope MXT4 Multi-Frequency Datalogging Signal Generator will provide a clear audible alert when issuing a signal output. This alert can be switched off using the audio mute control.

High-Resolution Backlit Digital Display

The selected frequency signal output, function and power level are all displayed on the C.Scope MXT4 Multi-Frequency Datalogging Signal Generator’s easy-to-read, backlit LCD which is mounted behind a protective polycarbonate lens. Via the display, the user can also view the connection quality, battery condition and the results of the Automatic Daily Self Test (ADST).

Automatic Daily Self Test (ADST)

Upon initial start-up, the C.Scope MXT4 Multi-Frequency Datalogging Signal Generator will perform an Automatic Daily Self Test. The results of this test are automatically saved to the C.Scope MXT4 Multi-Frequency Datalogging Signal Generator’s in-built memory. A positive result indicates that the C.Scope MXT4 Multi-Frequency Datalogging Signal Generator is working correctly.

ADST results can be downloaded to a PC anytime within the following twelve months. Once downloaded they can be used with the C.Scope PC Toolkit (NOT included) to create a Product Validation Certificate. The C.Scope PC Toolkit can also be used to access the C.Scope MXT4 Multi-Frequency Datalogging Signal Generator’s original calibration certificate.

As the C.Scope MXT4 Multi-Frequency Datalogging Signal Generator performs Automatic Daily Self Tests, the need for periodic recalibration is negated.

Datalogging

In addition to saving ADST results, the C.Scope MXT4 Multi-Frequency Datalogging Signal Generator and C.Scope MXL4 Datalogging Precision Cable Locator have the capacity to save up to a year’s worth of data between them. Data can be transferred to a PC at any time via a USB interface.

Robust, Durable and Ergonomic Design

This IP65 Genny features a twin-wall design to ensure it is suitable for rugged, challenging outdoor environments. Furthermore, the C.Scope MXT4 Multi-Frequency Datalogging Signal Generator’s large base doubles as an accessory tray capable of storing an instruction manual as well as all the standard accessories supplied with this unit, and additional OPTIONAL accessories such as a signal clamp, sondes and signal injectors.

The C.Scope MXT4 Multi-Frequency Datalogging Signal Generator is a versatile, reliable and resilient Genny optimised for use with C.Scope’s MXL4 CATs.

C.Scope MXT4 Multi-Frequency Datalogging Signal Generator Key Features

  • A signal transmitter designed for use with C.Scope’s MXL4 Datalogging Precision Cable Locators
  • Energise a wide variety of pipes and cables
  • Use with the MXL4 Cable Locator to identify, pinpoint and trace buried pipes, cables and utilities
  • Frequency range: 512/640Hz to 131kHz
  • Supports dual-frequency signal output: 33kHz and 131kHz
  • Support for multiple frequency signal outputs maximises the number of buried utilities that are energised
  • Support for multiple frequency signal outputs improves long-distance utility tracing and identification in congested sites
  • Supports three signal application techniques: Direct Connection, Wraparound and Induction
  • Adjustable one-watt power output
  • Adjustable power output enables deeper pipes to be energised and traced over longer distances
  • Four-position power level adjustment for complete control over power application
  • Supports pulsed or continuous signal output
  • Switch from Continuous mode to Pulse mode at the push of a button
  • Pulse mode is suitable for tracing utilities in high interference situations
  • Provides a clear audible alert when issuing a signal output
  • Switch the audible alert off using the audio mute control
  • Easy-to-read, backlit, high-resolution display mounted behind a protective polycarbonate lens
  • The frequency signal output, function, power level, connection quality, battery condition and ADST results are all indicated on the display
  • Performs an Automatic Daily Self Test (ADST) upon initial start-up
  • ADST results are saved to the in-built memory
  • A positive ADST result indicates the equipment is working correctly
  • ADST results can be downloaded to a PC within 12 months and used to create a Product Verification Certificate (C.Scope PC Toolkit required)
  • ADST removes the need for periodic calibration
  • Datalogging: save up to a year’s worth of data on the MXT4 Genny and MXL4 CAT
  • Transfer saved data to a PC via a USB interface
  • IP65
  • Twin-wall design to ensure suitability for rugged, challenging, outdoor environments
  • Large base doubles as an accessory tray
  • Versatile, reliable and resilient Genny optimised for use with C.Scope’s MXL4 CAT

What’s Included?

  • C.Scope MXT4 Multi-Frequency Datalogging Signal Generator
  • Direct Connection Leads
  • Earth Stake
  • Connection Magnets
  • 10m Auxiliary Earth Lead
  • Instruction Manual

C.Scope MXT4 Multi-Frequency Datalogging Signal Generator Technical Specifications 

Controls
All operation is by push button control as follows: On/Off
Power Level: Cycles through four available power levels
Frequency: cycles through six available output frequencies
Pulse/Continuous Output: toggles between pulse or continuous output using one push button
Audio Output: toggles between loud, muted and silent audio output using one push button
Audio Indications




Audio Feedback on button push
Audio pitch drops with increasing load current in Connected Mode
Audio pitch changes with power level in Induced Mode
Audio output pulses to indicate Pulsed Mode
Low battery indicated by interrupted Audio and output signal
Visual Indication
Multi-segment Liquid Crystal Display indicating: Output Frequency
Pulse Mode
Continuous Mode
Battery Condition
Output Level (bargraph)
Speaker Mute
Self Test Result
Data Connector Standard USB Mini B connector. USB 2.0 Compatible
Self Test Automatic Daily Self Test and manual Self Test function
Output Induced = 131,072Hz and 32,768Hz; 131,072Hz, 32,768Hz and 8,192Hz
Connected = 131,072Hz and 32,768Hz; 131,072Hz, 32,768Hz; 8,192Hz; 640 and 512Hz
Carrier Pulse Frequency: 7.5Hz (pulsed mode)
Connected Mode Connection Mode automatically selected when lead is plugged into socket
Maximum Output Voltage (open circuit): 30V rms
Maximum Output Current (short circuit): 65mA rms
Maximum Power: 1W into 400Ω load
Construction Case moulded from high impact plastic.
Designed to withstand 1m (3’3”) drop onto a hard surface
Incorporates clip-on accessory storage compartment
Weight (including batteries, Connection Leads and Earth Stake) 3.4kg (7 lb 7 oz)
Dimensions (with Accessory Tray fitted) 360mm x 180mm x 230mm (14.1” x 7” x 9”)
Battery Type Internal 4 x ‘D’ (LR20) cells (either alkaline non-rechargeable or NiMH rechargeable)
Battery Life up to 40 hours intermittent use at 20ºC (68ºF) using alkaline cells
IP Rating 65
Notes

Network Rail Approved
Performance figures stated can be affected by site parameters such as ground conditions, temperature, and strong electromagnetic fields. Specification may be subject to change. All C.Scope Transmitters are in compliance with the essential requirements and other relevant provisions of Council Directive 2014/53/EU (EMC). Compliance has been demonstrated by testing representative samples to the harmonised standards EN300-330 and EN301-489. The essential radio test suites have been carried out and the equipment is in conformity with all applicable directives. All C.Scope Transmitters comply with the essential requirements and other provisions of Council Directive 2011/65/EU (RoHS).
One Watt Power Yes
Four Power Levels Yes
Transmitter Frequency: 33+131kHz (Connected and Induced) Yes
Transmitter Frequency: 131kHz (Connected and Induced Yes
Transmitted Frequency: 33kHz (Connected and Induced) Yes
Transmitted Frequency: 8kHz (Connected and Induced) Yes
Transmitted Frequency: 512Hz (Connected) Yes
Transmitted Frequency: 640Hz (Connected) Yes
Pulsed / Continuous Output Signal Yes
Direct Connection Signal Mode Yes
Wraparound Signal Mode Yes
Induction Signal Mode Yes
Automatic Daily Self Test Yes
Data Logging Yes
Data Transfer via USB Yes
High-Resolution Backlit Liquid Crystal Display Yes
No Periodic Calibration* Yes
Three Year Warranty** Yes
Batteries*** 4 x D (LR20) Alkaline or NiMH Rechargeable Yes
In-Built Accessory Tray**** Yes
IP65 Yes
Notes No Periodic Calibration. The MXT4 does not require periodic recalibration. A Product Validation Certificate can be printed using the PC Toolkit. C.Scope authorised Service Centres are also able to provide third-party Test and Calibration Certification should you require it to comply with client or internal regulations.
** Three Year warranty. Conditions apply.
*** Batteries. 4 x D LR20 Alkaline or NiMH Rechargeable batteries housed in a secure battery compartment.
**** In-Built Accessory Tray includes Direct Connection Lead, Auxiliary 10m Earth Lead, Connection Magnets, Earth Stake and Instruction Manual.
Accessories related to this product:
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:C.Scope MXT4 Multi-Frequency Datalogging Signal Generator
Your Rating
Additional Information
SKU MXT4-D
Manufacturer Part Code MXT4-D
Country of Origin United Kingdom
International Enquiry