Fluke's 83V digital multimeter is built for use in industrial applications, and is robust and versatile enough to carry out a wide variety of testing procedures on industrial-grade equipment and machinery.
As standard the 83V is able to carry out voltage testing on both AC and DC up to 1000V, resistance testing up to 10A, 20A for up to 30 seconds, frequency measurements and continuity/diode testing procedures. It can also be used to measre capacitance, with 10000μF capacitance range for components and motor caps.
The Fluke 83V includes an array of additional features that are useful in industrial environments such as MIN/MAX average recording, peak capture that can record transiests quickly and a relative mode to remove test lead interference. The multimeter is also entirely auto or manual ranging depending on preference, and includes various other additional features as well.
Fluke 83V Industrial Digital Multimeter Key Features
Large display digits and bright backlit screen for high visibility
10000μF capacitance range for components and motor caps
Measures up to 1000V AC and DC
Measures up to 10A, 20A for up to 30 seconds
Auto and manual ranging
Analogue bargraph
Resistance, continuity and diode testing procedures
Frequency and duty cycle measurements
MIN/MAX and average recording
Relative mode
Sleep mode enhances battery life
Access door for batteries without breaking calibration seal
Removable holster
CAT IV 600V and CAT III 1000V electrical safety ratings
What's Included?
Fluke 83V Industrial Digital Multimeter
TL75 Test Leads
AC72 Alligator Clips
Holster
9V Battery
CD-ROM (User's Manual and Technical Notes)
Operator's Guide
£435.00
£522.00 inc vat
Free Delivery*
2 in Stock:Available Next Working Day*
Important Notice This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
Spend £150+ (Ex VAT) on any qualified Fluke or Beha-Amprobe product(s) and claim a free tool of your choice from the list at Fluke Promotion. Valid February 17 2025 - July 31 2025.
Claims are made direct to Fluke. Terms and conditions apply.
FREE Oxford Carry Case
PASS Oxford Black Small Test Equipment Carry Case - PASSCASE-SM, typically £14.99
Technical Information
Specification
Technical Specifications
Voltage DC
Maximum Voltage:
1000V
Accuracy:
Fluke 83 V: ±(0.1%+1)
Fluke 87 V: ±(0.05%+1)
Maximum Resolution:
Fluke 83 V: 100 µV
Fluke 87 V: 10 µV
Voltage AC
Maximum Voltage:
1000V
Accuracy:
Fluke 83 V: ±(0.5%+2)
Fluke 87 V: ±(0.7%+2) True RMS
AC Bandwidth
Fluke 83 V: 5kHz
Fluke 87 V: 20kHz*
*with low pass filter; 3db @ 1kHz
Maximum Resolution:
0.1 mV
Current DC
Maximum Amps:
10A (20 A for 30 seconds maximum)
Amps Accuracy:
Fluke 83 V: ±(0.4%+2)
Fluke 87 V: ±(0.2%+2)
Maximum Resolution:
Fluke 83 V: 0.01 mA
Fluke 87 V: 0.01 µA
Current AC
Maximum Amps:
10A (20 A for 30 seconds maximum)
Amps Accuracy:
Fluke 83 V: ±(1.2%+2)
Fluke 87 V: ±(1.0%+2) True RMS
Maximum Resolution:
0.1 µA
Resistance
Maximum Resistance:
50 MΩ
Accuracy:
Fluke 83 V: ±(0.4%+1)
Fluke 87 V: ±(0.2%+1)
Maximum Resolution:
0.1Ω
Capacitance
Maximum Capacitance
9,999 µF
Accuracy
±(1%+2)
Maximum Resolution
0.01 nF
Frequency
Maximum Frequency
200 kHz
Accuracy
±(0.005%+1)
Maximum Resolution
0.01 Hz
Duty Cycle
Maximum Duty Cycle
99.9%
Accuracy
±(0.2% per khz +0.1%)
Maximum Resolution
0.1%
Temperature Measurement
Fluke 87 V, 87 V/E:
-200.0°C - 1090°C
-328.0°F - 1994.0°F
excluding probe
80 BK Temperature Probe
-40.0°C - 260°C
-40.0°F - 500°F, 2.2°C or 2% whichever is greater
Conductance
Maximum Conductance
60.00 nS
Accuracy
±(1.0%+10)
Maximum Resolution
0.01 nS
Diode
Range:
3 V
Resolution:
1 mV
Accuracy:
± (2 % + 1)
Duty Cycle Range
Accuracy:
Within ± (0.2% per kHz + 0.1 %)
Environmental Specifications
Operating Temperature
-20°C to +55°C
Storage Temperature
-40°C to +60°C
Humidity (Without Condensation)
0% - 90% (0°C - 35°C)
0% - 70% (35°C - 55°C)
Operating Altitude
2000 m
Safety Specifications
Overvoltage category
EN 61010-1 to 1000 V CAT III, 600V CAT IV
Agency Approvals
UL, CSA, TÜV, VDE listed
Mechanical & General Specifications
Size
201 x 98 x 52 mm (with holster)
Weight
355 g
Weigh With Holster and Flex-Stand
624 g
Display
Digital:
6000 counts updates 4/sec.
(Model 87 also has 19,999 counts in high-resolution mode.)