All Fluke Products

Fluke 1732 Three-Phase Electrical Energy Logger - Choice of Version

SKU
FLUKE1732
Rating:
0%
(0)
Reward Points
:
2998
£2,998.80 £2,499.00
1 Option in Stock Free UK Delivery*
Choose a Special Offer
  • Tolsen Tools Electrician's 14-Piece Insulated Tool Kit
    Tolsen Tools Electrician's 14-Piece Insulated Tool Kit
    FREE
    £79.00
  • Tolsen Tools Electrician's 14-Piece Insulated Tool Kit SKU: (TS-900013)
    FREE
    £79.00
    Tolsen Tools Electrician's 14-Piece Insulated Tool Kit
Advice & Support
Price Match Request
Free Tool Kit
Fluke 1732 Three-Phase Electrical Energy Logger
Buy a Fluke Get a Free Fluke Logo

* Buy a Fluke (Worth £150+ Ex VAT) and Choose a Free Fluke!

Available until 31/08/24. For more details and to see your choice of free Fluke tool - View Offer

Only available from authorised Fluke distributors, such as PASS Ltd. Terms and conditions apply.

Please note that there are three versions of this kit available. The following table shows the difference between each.

You can select an option using the dropdown box above.

  Fluke-1732-B - Basic Version FLUKE-1732-EUS, EU/US Version FLUKE-1732-INTL, International Version
Fluke Connect Module Support Optional Optional Optional
Trend Recording
USB Mini B Communication
WiFi Download Optional
WiFi Download Via WiFi Access Point (requires Registration) Optional Optional Optional
Included Accessories
WiFi and BLE Adapter Optional Optional Optional
USB Flash Drive (4GB) - - -
USB Cable
3PHVL-173 Flat Cable
1 x Red, 1 x Black 0.1m Cable
1 x Red, 1 x Black 1.5m Lead
Alligator Clips 4 4 4
C173x Soft Case
Colour Coding Set
173x Hanger Kit Optional Optional Optional
MP1-Magnet Probe Optional Optional Optional
i173x-flex 1500 12" Flexible Current Clamps Optional 3 3
Line Cord EU, UK, US, AUS, BR EU, US, UK EU, UK, US, AU, BR

Reduce your energy usage with the comprehensive Fluke 1732, a portable energy logger designed to help you determine exactly where you're wasting energy needlessly.

Suitable for installation anywhere from the service entrance to on individual circuits, the Fluke 1732 helps you to create a detailed profile of your energy usage, allowing you to identify opportunities for saving energy while at the same time giving you the data you need to act upon these opportunities.

See for yourself how the 1732 can change your facilities' operation in this video from Fluke.

What Can the Fluke 1732 Energy Logger be Used For?

Equipped with everything you need for logging a wide variety of power, electrical and energy measurements, the 1732 is an ideal instrument for use in a wide variety of applications.

The kit ships as standard with 3 flexible current probes, allowing you to measure on all three phases as the same time.

Applications for the Fluke 1732 energy logger include:

  • Load Studies - you can use the Fluke 1732 to determine how much energy individual pieces of equipment consume and if they are operating at maximum and minimum capacity
  • Energy Assessments - quanitify your energy consumption before and after improvements, helping you to justify the installation of energy-saving equipment
  • Energy Surveys - create a comprehensive, detailed log on every electrical system in your facility, starting from main service feeders all the way down to larger loads
  • Assess Operating Conditions - the Fluke 1732 is also able to log related measurements such as temperature, voltage, current or pressure, allowing you to determine the efficiency and operating conditions of your equipment

Comprehensive Power, Energy and Electrical Assessments & Logs

Fluke 1732 energy loggers are designed to measure all of the most critical three-phase power parameters and log all critical data directly in built-in memory storage, ready for download to your PC after measurements are completed.

These energy loggers can store more than a year's worth of data, making them fully suitable for longer studies and gaining the detailed information you need to make a full energy assessment of your facility.

Better still, Fluke 1732 energy loggers will simultaneously and automatically log all of the following parameters:

  • RMS Voltage - with measurement range of up to 1000V and resolution as low as 0.1V
  • Current - 12", flexible current probes are included as standard, allowing measurements of up to 1500A. This range can be expanded further by buying additional Fluke clamp probes (sold separately) up to a high range of 6000A (see the optional accessories section for more information)
  • Power Measurements - the Fluke 1732 will log active power, reactive power and power factor
  • Energy Measurements - this logger can store active and reactive energy measurements

See Everything with Fluke's Energy Analyse Plus Software, Included as Standard

Once you've logged all of your data, you need useful software to view all of your results and to see where you can make savings.

Fluke's Energy Analyse Plus software, which is included in your 1732 energy logger pack or available for download from the Fluke website, gives you all of the tools you need to create useful information and reports for your own use, or for sharing with others.

The software includes powerful analysis tools and gives you the ability to create fully customised reports in minutes. You can also quickly and easily compare any measured parameter.

Additional Benefits

There's even more to the Fluke 1732 than just its powerful measurement capabilities! Users can expect:

  • Fully Comprehensive Logging - store more than 20 separate logging sessions on the instrument with the ability to view all results in real-time
  • Optimised User Interface - quick, guided graphical setup screens ensure you're capturing the right data with every log
  • Intelligent Verification - the Fluke 1732 will detect and warn you about incorrect connections
  • Bright, Full Colour Touch Screen - ideal for in-the-field analysis and data checks
  • Upgradeable Design - the Fluke 1732 can be upgraded at a later data to unlock similar features to the upgraded model, the Fluke 1734. New features include fully integrated logging wirelessly via Fluke Connect and even more detailed logging capabilities

What's Included In the Kit?

When purchasing this kit, you will receive:

  • Fluke 1732 Energy Logger
  • Power Supply
  • Voltage Test Leads
  • 4 x Alligator Clips
  • 3 x 12 Inch, 1500A Flexible Current Probes
  • Soft Carrying Case
  • Energy Analyse Plus Software
  • Line Cords
  • Colour Coding Se

Optional Accessories

Expand the capabilities of your Fluke 1732 with these optional items.

If you'd like more information about a product, please search for it on our website or - if not available - please call the sales team directly for additional information.

  • 173X-AUX Analogue Adapter
  • i17xx-flex 1500 12" Current Probe
  • i17xx-flex 3000 24" Current Probe
  • i17xx0flex 6000 36" Current Probe
  • i40s-EL Current Clamp
  • 1732/Upgrade - Upgrades the 1732 to the 1734

Fluke 1732 Technical Specifications

Accuracy
Parameter Range Resolution Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale)
Voltage 1000 V 0.1 V ±(0.2% + 0.01%)
Current: Direct input i17xx-flex 1500 12" 150 A 0.1 A ±(1% + 0.02%)
1500 A 1 A ±(1% + 0.02%)
i17xx-flex 3000 24" 300 A 1 A ±(1% + 0.03%)
3000 A 10 A ±(1% + 0.03%)
i17xx-flex 6000 36" 600 A 1 A ±(1.5% + 0.03%)
6000 A 10 A ±(1.5% + 0.03%)
i40s-EL clamp 4 A 1 mA ±(0.7% + 0.02%)
40 A 10 mA ±(0.7% + 0.02%)
Frequency 42.5 Hz to 69 Hz 0.01 Hz ±(0.1%)
Auxillary input ±10 V dc 0.1 mV ±(0.2% + 0.02%)
Voltage min/max 1000 V 0.1 V ±(1% + 0.1%)
Current min/max Defined by accessory Defined by accessory ±(5% + 0.2%)
THD on voltage 1000% 0.1% ±0.5
THD on current 1000% 0.1% ±0.5
Intrinsic Uncertainty ±(% of reading +% of range)¹
Parameter Influence quantity iFlex1500-12 iFlex3000-24 iFlex6000-36 i40S-EL
150 A / 1500 A 300 A / 3000 A 600 A / 6000 A 4 A / 40 A
Active Power P PF ≥ 0.99 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Active Energy Ea PF ≥ 0.99 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Apparent power S 0 ≤ PF ≤ 1 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Apparent Energy Eap 0 ≤ PF ≤ 1 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Reactive power Q 0 ≤ PF ≤ 1 2.5% of measured apparent power
Reactive Energy Er 0 ≤ PF ≤ 1 2.5% of measured apparent power
Power Factor PF - ±0.025
Displacement Power Factor - ±0.025
DBF/cosϕ - ±0.025
Additional uncertainty in% of range¹ VP-N>250 V 0.015% 0.0225% 0.0225% 0.015%
¹Range = 1000 V x Irange
Reference conditions:
  • Environmental: 23 °C ±5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65%
  • Input conditions: Cosϕ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10%.
  • Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V Input current: I > 10% of Irange
  • Primary conductor of clamps or Rogowski coil in center position
  • Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

 

Electrical Specifications
Power Supply
Voltage range 100 V to 500 V using safety plug input when powering from the measurement circuit
100 V to 240 V using standard power cord (IEC 60320 C7)
Power consumption Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Efficiency ≥ 68.2% (in accordance with energy efficiency regulations)
Maximum no-load consumption < 0.3 W only when powered using IEC 60320 input
Mains power frequency 50/60 Hz ±15%
Battery Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtime Four hours in standard operating mode, up to 5.5 hours in power saving mode
Charging time < 6 hours
Data Acquisition
Resolution 16-bit synchronous sampling
Sampling frequency 10.24 kHz at 50/60 Hz, synchronized to mains frequency
Input signal frequency 50/60 Hz (42.5 to 69 Hz)
Circuit types 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies)
Data storage Internal flash memory (not user replaceable)
Memory size Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events¹
¹The number of possible logging sessions and logging period depends on user requirements.
Basic Interval
Measured parameters Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
Averaging interval User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging time min/max values Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms
Demand Interval (Energy Meter Mode)
Measured parameters Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
Interval User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
Standards Compliance
Power IEEE 1459
Interfaces
USB-A File transfer via USB flash drive, firmware updates
Max. current: 120 mA
WiFi File transfer and remote control via direct connection or WiFi infrastructure
Bluetooth Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1734, or 1732 upgrade option)
USB-mini Data download device to PC
Voltage Inputs
Number of inputs 4 (3 phases and neutral)
Maximum input voltage 1000 Vrms, CF 1.7
Input impedance 10 MΩ
Bandwidth (-3 dB) 42.5 Hz - 3.5 kHz
Scaling 1:1 and variable
Measurement category 1000 V CAT III/600 V CAT IV
Current Inputs
Number of inputs 3, mode selected automatically for attached sensor
Input voltage Clamp input: 500 mVrms/50 mVrms; CF 2.8
Rogowski coil input 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Range 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12"
3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24"
6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36"
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
Bandwidth (-3 dB) 42.5 Hz - 3.5 kHz
Scaling 1:1 and variable
Auxiliary Inputs
Number of inputs 2
Input range 0 to ±10 V dc, 1reading/s
Scale factor (available 2014) Format: mx + b (gain and offset) user configurable
Displayed units (available 2014) User configurable (7 characters, for example, °C, psi, or m/s)
Wireless Connection
Number of inputs 2
Supported modules Fluke Connect® 3000 series
Acquisition 1 reading/s
Environmental Specifications
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F)
Operating humidity 10 °C to 30 °C (50 °F to 86 °F) max. 95% RH
30 °C to 40 °C (86 °F to 104 °F) max. 75% RH
40 °C to 50 °C (104 °F to 122 °F) max. 45% RH
Operating altitude 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage altitude 12,000m
Enclosure IP50 in accordance with EN60529
Vibration MIL-T-28800E, Type 3, Class III, Style B
Safety IEC 61010-1
IEC Mains Input: Overvoltage Category II, Pollution Degree 2
Voltage Terminals: Overvoltage Category IV, Pollution Degree 2
IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V
Electromagnetic compatibility EN 61326-1: Industrial CISPR 11: Group 1, Class A
Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Temperature coefficient 0.1 x accuracy specification/°C
General Specifications
Color LCD display 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
Warranty Instrument and power supply: Two-years (battery not included)
Accessories: one-year
Calibration cycle: two-years
Dimensions Instrument: 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 in)
Power supply: 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 in)
Instrument with power supply attached: 19.8 x 16.7 x 9 cm (7.8 x 6.6 x 3.5 in)
Weight Instrument: 1.1 kg (2.5 lb)
Power supply: 400 g (0.9 lb)
Tamper protection Kensington lock slot
i17xx-flex 1500 12" Flexible Current Probe Specifications
Measuring range 1 to 150 A ac/10 to 1500 A ac
Nondestructive current 100 kA (50/60 Hz)
Intrinsic error at reference condition* ±0.7% of reading
Accuracy 173x + iFlex ±(1% of reading + 0.02% of range)
Temperature coefficient over operating temperature range 0.05% of reading/°C 0.09% of reading/°F
Working voltage 1000 V CAT III, 600 V CAT IV
Probe cable length 305 mm (12 in)
Probe cable diameter 7.5 mm (0.3 in)
Minimum bending radius 38 mm (1.5 in)
Output cable length 2 m (6.6 ft)
Weight 115 g
Probe cable material TPR
Coupling material POM + ABS/PC
Output cable TPR/PVC
Operating temperature -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F)
Temperature, non-operating -40 °C to +80 °C (-40 °F to 176 °F)
Relative humidity, operating 15% to 85% non-condensing
IP rating IEC 60529:IP50
Warranty One-year
* Reference condition:
  • Environmental: 23 °C ±5 °C, no external electrical/magnetic field, RH 65%
  • Primary conductor in center position
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Fluke 1732 Three-Phase Electrical Energy Logger - Choice of Version
Your Rating
Additional Information
SKU FLUKE1732
Manufacturer Part Code 4706548
International Enquiry