The Beha-Amprobe HD160C is built for use in the most demanding of applications, and comes with waterproof, extremely rugged protection against various types of stresses such as dirt, grime, moisture, grease, shock and even chemical spillages. It can also be dropped from a height of up to eight feet and still keep in perfect working order.
Since it's so resistant, the Beha-Amprobe HD160C is ideal for on-site work, particularly in environments where testers could be easily damaged. It's also suitable for use on extremely high voltage systems, and boasts one of the highest voltage measurement ranges available on the market today (1500V DC and 1000V AC).
The HD160C is also an autoranging multimeter, and will adjust itself as necessary when performing testing procedures. As well as voltage testing, the HD160C is also able to measure capacitance, current, resistance, continuity temperature and frequency, with all results relayed to the multimeter's 10000 count screen with bar graph and numerical representation of testing results. Results for AC current and voltages are true RMS.
Beha-Amprobe HD160C Heavy Duty Multimeter Key Features
- High voltage capability (1500V DC and 1000V AC)
- CAT IV 1000V rated
- IP67 protection protects the device against environmental conditions and water
- Constructed using special drop-resistant housing and PCB mounting
- Measures capacitance, temperature and frequency
- 10000 count resolution with bar graph
- Bright backlight for using the device in darkened conditions
- Magne-grip holster allows users to mount the tester for hands-free operation
- Includes high voltage test leads
- Temperature measurement capabilities
- Frequency measurements built-in
- Capacitance testing
- Automatic polarity indication
- Auto power down
Full List of Products Included
- Beha-Amprobe HD160C Heavy Duty Multimeter
- Test Leads
- Batteries (Installed)
- User Manual
- Magne-Grip Holder with Magnetic Hanging Strap
Beha-Amprobe HD160C Technical Specifications
General Specifications | |
---|---|
Display | 4 digit LCD, 9999 counts, with annunciators, menu features and 41 segment bargraph |
Polarity Indication | Automatic |
Input Overload Indication | OL, -OL |
Low Battery Indication | Symbol at less than 50 hours battery life remaining (accuracy no longer guaranteed) |
Display Update Rate | 2/sec nominal; 20/sec for bargraph |
Operating Temperature | 0 to +50°C @ 0 to 75% RH |
Storage Temperature | -20 to 60°C @ 0 to 80% RH, battery removed |
Altitude | 2000m - indoor use |
Temperature Coefficient | 0.1 x (spec. accuracy)/°C (0 to 18°C and 28 to 50°C) |
Fuse | F 2A/1500V fuse (8mm x 65mm), I.R. 30kA - Amprobe p/n FP700 |
Power | Standard 9V battery, NEDA 1604, JIS 006P, IEC 6F22 |
Auto Power Down | Meter powers down after approximately 30 minutes of inactivity. Not in MIN/MAX function |
Battery Life (Typical) | 150 hours, alkaline. Backlight usage consumes extra power and will decreased battery life significantly. Backlight auto off after approx 30 seconds |
Dimensions (Without Holster) | 200 x 102 x 59mm (7.9 x 4.0 x 2.3") - H x W x D |
Weight (Incl. Battery) | 642g (22oz) |
Safety | Meets EN 61010-1 CAT IV 1000V (1500V DC max) Class II, EN 60529: IP67 |
EMC | Meets EN 61326-1 |
Electrical Specifications | |
DC Voltage | |
Ranges | 1000mV, 10V, 100V, 1500V |
Resolution | 0.1mV in 1000mV range |
Accuracy | ±(0.1% rdg + 5 digits) |
Input Impedance | 10MΩ |
CMRR | >120dB up to 1500V DC |
NMRR | >60dB at 50/60Hz |
OL Protection | 1500V DC or 1000V AC RMS |
Transient Protection | 12kV impulse (1.2μS/50μS) based on EN 61010-1:2001 impulse requirements for CAT IV 1000V/1500V DC products. This product should not be used in installations where transients exceed 12kV |
AC Voltage (True RMS) | |
Ranges | 1000mV, 10V, 100V, 1000V |
Resolution | 0.1V in 1000mV range |
Accuracy | 1000mV (45 to 400Hz): ±(1.2% rdg + 10 digits) 10V, 100V (45 to 500Hz): ±(1.2% rdg + 10 digits) 10V, 100V (500Hz to 2kHz): ±(2.0% rdg + 10 digits) 1000V (45 to 1kHz): ±(2.0% rdg + 10 digits) |
Input Impedance | 10MΩ |
Conversion Type | True RMS, AC coupled 5% to 100% of range |
Crest Factor | ≤3 |
OL Protection | 1500V DC or 1000V AC RMS |
Transient Protection | 12kV impulse (1.2μS/50μS) based on EN61010-1:2001 impulse requirement for CAT IV 1000V products. This product should not be used in installations where transients exceed 12kV |
DC Current | |
Ranges | 100μA, 1000μA, 10mA, 100mA, 400mA, 2A (auto/manual ranging) |
Resolution | 0.01μA in 100μA range |
Accuracy | 100μA range: ±(0.5% rdg + 10 digits) 1000μA to 400mA ranges: ±(0.5% rdg + 5 digits) 2A range: ±(1.5% rdg + 10 digits) |
Input Protection | 2A/1500V fast blow ceramic fuse 8 x 65mm on A input, FP700 |
Burden Voltage | μA range of 1mV/1μA, mA range of 10mV/1mA, 2A range of 500mV/1A, 500mV max. (2V max on 1000μA, 100mA, 400mA, 2A ranges) |
OL Protection | A input (F 2A/1500V, size 8 x 65mm IR fast blow ceramic) |
AC Current (True RMS) | |
Ranges | 100μA, 1000μA, 10mA, 100mA, 400mA, 2A |
Resolution | 0.01μA in 100μA range |
Accuracy (45 to 1kHz) | 100μA to 100mA: ±(1.5% + 10 digits) 400mA: ±(2.0% + 10 digits) 2A: ±(2.5% + 20 digits) |
Voltage Burden | See DC current |
Conversion Type | True RMS AC couple 10 to 100% of range |
Crest Factor | ≤3 |
OL Protection | See DC current |
Resistance | |
Ranges | 1000Ω, 10kΩ, 100kΩ, 1000kΩ, 10MΩ, 40MΩ |
Resolution | 0.1Ω in 1000Ω range |
Accuracy | 1000Ω to 1000kΩ: ±(0.5% rdg + 8 digits) 10MΩ: ±(1.0% rdg + 10 digits) 40MΩ: ±(2.0% rdg + 10 digits) |
Overload Protection (All Ranges) | 1500V DC or 1000V AC RMS |
Continuity | |
Audible Indication | Less than 40Ω |
Response Time | 100ms |
Overload Protection | 1500V DC or 1000V AC RMS |
Capacitance | |
Ranges | 40nF, 400nF, 4μF, 40μF, 400μF (3999 counts) - auto/manual ranging |
Resolution | 0.01nF |
Accuracy | 40nF, 400μF: ±(3.0% rdg + 10 digits) 400nF to 40μF: ±(3.0% rdg + 5 digits) |
Test Voltage | <1V |
Test Frequency | 1.3Hz on 40nF to 40μF ranges; 0.7Hz on 400μF range |
Overload Protection | 1500V DC or 1000V AC RMS |
Temperature | |
Ranges | -20 to 1300°C (-4 to 2372°F) |
Resolution | 1°C, 1°F) |
Accuracy | -20 to 10°C: ±(2.0% rdg + 4°C) 10 to 200°C: ±(1.0% rdg + 3°C) 200 to 1300°C: ±(2.0% rdg + 2°C) |
Frequency | |
Ranges | 100Hz, 1000Hz, 10kHz, 100kHz, 1000kHz, 10MHz |
Resolution | 0.01Hz on 100Hz range |
Accuracy | ±(0.1% rdg + 5 digits) |
Sensitivity | 3Hz to 1mHz: >2.5V AC RMS 1mHZ to 10mHZ: >2.5V AC RMS, <5V AC RMS |
Minimum Input Range | 100Hz range: >3Hz 1000Hz range: >30Hz |
Minimum Pulse Width | >25ns |
Duty Cycle Limits | >30% and <70% |
Overload Protection | 1500V DC or 1000V AC RMS |
SKU | 2670787 |
---|---|
Manufacturer Part Code | 2670787 |
Country of Origin | Taiwan |