All Fluke Products

Fluke 377 True-RMS Non-Contact AC/DC Clamp Meter

SKU
FLUKE377
Rating:
0%
(0)
Reward Points (?)

Logged in, worth £14.04, read more.

:
1404
As low as £702.00 £585.00
Free UK Delivery* Delivery Options

UK - Zone 1 Orders

England, Wales & most of Scotland.

Free 3-7 Working Day1
Orders Over £99 & Selected Items

Standard 2-7 Working Day1
From £1.95

Tracked 2-3 Working Day
£4.95

Express Next Working Day
£7.95

Priority Next Working Day
£14.95 (Pre-Noon)
£19.95 (Pre-10:30am)

Saturday & Sunday
£14.95 (Pre-Noon)

UK - Zone 2 Orders

Highlands, Islands & Northern Ireland.

Free 3-7 Working Day1
Selected Items (Calculated at Checkout)

Standard 2-7 Working Day2
From £1.95

Tracked 2-3 Working Day
£9.95

International Orders

Delivery is calculated at checkout.


Note: Next day delivery is not guaranteed for orders placed after 3:00pm. Prices Ex VAT.

1, 2 See delivery page for more details.

Advice & Support
Price Match Request

The Fluke 377 True-RMS Non-Contact AC/DC Clamp Meter is a voltage and current clamp meter with FieldSense technology and an iFlex probe. There are two versions of this clamp available: one with Fluke Connect and one without. Please see the table below for further details.

SKU Title
FLUKE377/E Fluke 377 & iFlex Probe (Without Fluke Connect)
FLUKE377FC/E Fluke 377 & iFlex Probe & Fluke Connect (With Fluke Connect)

 

Measure voltage and current without making contact with a live conductor. When a stable FieldSense measurement has been ascertained, the Fluke 377 True-RMS Non-Contact AC/DC Clamp Meter’s display will turn green. Similarly, when continuity is detected, the display will also turn green while the continuity beeper sounds. This makes it easy to identify continuity in loud environments.

The Fluke 377 True-RMS Non-Contact AC/DC Clamp Meter performs complete three-phase voltage and current tests in three quick and easy steps. An iFlex™ probe enables measurement of very high currents (up to 2500A) and provides access to large conductors in tight spaces.

In addition to voltage and current measurements, the Fluke 377 True-RMS Non-Contact AC/DC Clamp Meter can calculate a full set of phase-to-ground and phase-to-phase values, eliminating the need for manual sums. Models with Fluke Connect™ can be connected to a smartphone or tablet with the Fluke Connect App installed. This allows users to view and save measurements and results, as well as calculate Phase Rotation. Data can be monitored, logged, and analysed remotely allowing users to identify intermittent faults over prolonged periods of time.

Finally, the Fluke 377 True-RMS Non-Contact AC/DC Clamp Meter is supplied with a carry case capable of storing and transporting the Fluke 377, iFlex Probe, test leads, and black grounding clip. It is also supplied with a TPAK Magnetic Hanging Kit that can be used to hang the clamp meter on a steel door, pipe, nail, or screw.

The Fluke 377 True-RMS Non-Contact AC/DC Clamp Meter is a convenient and comprehensive voltage and current clamp meter.

Fluke 377 True-RMS Non-Contact AC/DC Clamp Meter Key Features

  • A voltage and current clamp meter with FieldSense technology and an iFlex probe
  • Two versions available: one with Fluke Connect and one without
  • Measure voltage and current without making contact with a live conductor
  • Backlit display
  • The display turns green when the continuity beeper sounds and when a stable FieldSense measurement is determined
  • Visual Continuity indication ensures continuity can be identified in noisy environments
  • Perform three-phase voltage and current tests in three easy steps
  • iFlex Probe enables measurement of high currents up to 2500A
  • iFlex Probe provides access to large conductors in tight spaces
  • Calculate a full set of phase-to-ground and phase-to-phase values
  • Optional Fluke Connect enables communication with smartphone/ tablet with the Fluke Connect App installed
  • Monitor log and trend data via the Fluke Connect App
  • View readings and results and calculate Phase Rotation via the Fluke Connect App
  • Supplied with a carry case capable of transporting the Fluke 377, iFlex Probe, test leads, and black grounding clip
  • Includes a TPAK Magnetic Hanging Kit
  • A convenient and comprehensive voltage and current clamp meter

What’s Included?

  • Your Choice of Fluke 377 True-RMS Non-Contact AC/DC Clamp Meter
  • Fluke TL224 Test Leads
  • Fluke TP175 TwistGuard™ Test Probes
  • Fluke AC285 Black Grounding Clip
  • Fluke i2500-18 iFlex Current Probe
  • Fluke TPAK Magnetic Hanging Kit
  • Carry Case
  • Quick Referene Guide
Part Code

Fluke 377 True-RMS Non-Contact AC/DC Clamp Meter Technical Specifications 

General Specifications 
General Maximum voltage
(between any terminal and earth
ground)
1000 V
Battery Life 200 hours
Battery Type 2 AA IEC LR6 alkaline
Display Dual readout
Automatic Power Off 20 minutes
AC Current: Jaw
Range 999.9 A
Resolution 0.1 A
Accuracy 2 % ± 5 digits (10 Hz to 100 Hz)
2.5 % ± 5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
Add 2 % for C.F. >2
AC Current: Flexible Current Probe
Range 2500 A
Resolution 1 A (≤ 2500 A) 0.1 A (≤ 999.9 A)
Accuracy 3 % ±5 digits (5 Hz to 500 Hz)
DC Current
Range 999.9 A
Resolution 0.1 A
Accuracy 2 % ±5 digits
AC Voltage: FieldSense
Range 1000 V
Resolution 1 V (≤ 1000 V)
Accuracy ≤ 4/0 AWG 3 % ±5 digits (45 Hz to 66 Hz)
Accuracy ≥ 4/0 AWG 5 % ±5 digits (45 Hz to 66 Hz)
AC Voltage: Test Leads
Range 600.0 V 1000 V
Resolution 0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1 % ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range 600.0 V
1000 V
Resolution 0.1 V ≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy 1 % ± 5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1 % ± 5 digits
Amps Frequency: Jaw
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % ± 5 digits
Trigger Level 5 Hz to 10 Hz, ≥ 10 A
10 Hz to 100 Hz, ≥ 5 A
100 Hz to 500 Hz, ≥ 10 A
Amps Frequency: Flexible Current
Probe
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % ±5 digits
Trigger Level 5 Hz to 20 Hz, ≥ 25 A
20 Hz to 100 Hz, ≥ 20 A
100 Hz to 500 Hz, ≥ 25 A
Resistance
Range 60.00 kΩ
6000 Ω
600.0 Ω
Resolution 0.1 Ω (≤ 600.0 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60.00 kΩ)
Accuracy 1 % ±5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100.0 μF)
1 F (≤ 1000 μF)
Accuracy 1 % ±4 digits
Mechanical
Size (L x W x H) 274 mm x 86 mm x 47 mm
Weight (with Batteries) 463 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Rogowski Coil Length 450 mm
Environmental
Operating Temperature -10 °C to 50 °C
Storage Temperature -40 °C to 60 °C
Operating Humidity (without
condensation)
Non condensing (<10 °C)
≤ 90 % RH (10 °C to 30 °C)
≤ 75 % RH (30 °C to 40 °C)
≤ 45 % RH (40 °C to 50 °C)
Temperature Coefficients Add 0.1 x specified accuracy for each degree C >28 °C or <18 °C
Ingress Protection IEC 60529: IP30 (jaw closed)
Operating Altitude 2000 m
Storage Altitude 12 000 m
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable Electromagnetic Environment
IEC 61326-2-2, CISPR 11: Group 1, Class B
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy
that is necessary for the internal function of the equipment itself.
Class B: Equipment is suitable for use in domestic establishments and in establishments directly
connected to a low voltage power supply network which supplies buildings used for domestic purposes.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a
test object.
Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or
user should take notice of it. This equipment is intended for use in business environments and not to be
used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause
15.103.
Safety
General IEC 61010-1: Pollution degree 2
Measurement IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
Current Clamp for Leakage Current Measurements IEC 61557-13: Class 2, ≤ 30 A/m
Wireless Radio
Radio Frequency Certification FCC ID: T68-FBLE IC:6627A-FBLE
Frequency Range 2405 MHz to 2480 MHz
Output Power <100 mW
Radio Frequency Data Go to www.fluke.com and search for “Radio Frequency Data for Class A”
(PN 4333628) SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke
declares that the radio equipment contained in this Product is in compliance
with Directive 2014/53/EU. The full text of the EU declaration is available at the
following internet address: www.fluke.com/declaration-of-conformity

 

Files & Downloads:

0 Reviews Overall Rating

Write a Review

Write Your Own Review
You're reviewing:Fluke 377 True-RMS Non-Contact AC/DC Clamp Meter
Your Rating

Subscribe to our Newsletter

International Enquiry