Metrel MI3102BT Eurotest XE Multifunction Installation Tester

Metrel MI3102BT Eurotest XE Multifunction Installation Tester

The Metrel MI3102BT Eurotest XE Multifunction Installation Tester can be used to check domestic, industrial, and medical installations, as well as test TT, TN, and IT earthing systems, and single- and multi-phase systems. To this end it includes an extensive selection of tests optimised for measuring various electrical parameters, these include:

Metrel MI3102BT Eurotest XE Multifunction Installation Tester

  • Insulation resistance tests with a selectable DC test voltage between 50V and 1000V
  • 200mA continuity test with a polarity change for PE conductors
  • 7mA continuity test for PE conductors (without tripping RCDs)
  • Loop/ line impedance measurements
  • Loop impedance test with a Trip Lock RCD function
  • True-RMS voltage measurement
  • True-RMS frequency measurement
  • Phase sequence test
  • Power and harmonics measurements
  • General RCD tests
  • Selectable RCD tests (choose from types AC, A, F, B, B+)
  • Earth resistance measurements using a 3-wire and 2-clamp method
  • First fault leakage current measurements (ISFL)
  • Insulation Monitoring Device (IMD) test

Further to this, it can be used with a Ro-adapter (NOT included) to measure specific earth resistance. Moreover, it can be configured to perform OPTIONAL true-RMS leakage and load current measurements and OPTIONAL illumination measurements; please contact our sales team for further details.

In addition to the above testing capabilities, the  MI3102BT Eurotest XE includes several automatic testing sequences designed to improve the ease and efficiency of testing. This instrument supports AUTO SEQUENCES® optimised for testing TT, TN, and IT earthing systems; it also features an automated testing procedure for RCDs. Additionally, it is capable of online voltage monitoring: this tester can monitor three voltages in real time.

Also adding to the efficiency of testing is the integrated help screens for on-site referencing, and fuse tables for evaluating line and loop impedance results. The integrated fuse and RCD tables enable it to determine whether these components have passed or failed the relevant tests. In addition to this, the Metrel MI3102BT features power and harmonics analysis.

Results can be saved to the tester and these measurements can be transferred to a PC via the tester’s integrated Bluetooth module and using the supplied Metrel EuroLink Pro Software. This software can also be used to create professional reports. Alternatively; these testers can transfer results to an Android smartphone or tablet via Bluetooth and the free Metrel EuroLink Android App (NOT included).

The tester includes an integrated charging unit and is supplied with rechargeable NiMH batteries.

The Metrel MI3102BT Eurotest XE Multifunction Installation Tester is ideal for checking a variety of electrical installations and systems in accordance with IEC/ EN 61557 specifications.

Applications

Power generation

  • Earthing and lightning protection in thermal energy power plants

Renewable energy sources

  • Generator stator testing
  • Lightning protection testing in wind plants
  • Two clamps method for measuring earth loops in a solar plant

Industrial installations

  • Specific earth resistance measurement methods

Low voltage electrical installation safety

  • Substation electrical safety
  • Mains bonding and touch voltages during fault
  • Switchboards and automatic trip-out protection
  • Public places electrical safety

Low voltage earthing and lightning protection

  • Earthing measurement with fall of potential method
  • 2-clamps method for measuring lightning and earth protection

Special locations 

  • Wet and outdoor locations
  • IT system
  • DC installations
  • EVSE construction and testing

Mobile installations

  • Emergency response vehicles
  • Telecommunication equipment in mobile installations

Hospital earthing and lightning protection 

  • Two clamps method for measuring lightning and earth protection
  • Hospital earthing measurement with fall of potential method
  • Mains bonding and touch voltages during fault current

Power supply and power distribution 

  • Hospital switchboards and automatic trip-out protection

Patient recovery rooms and hospital wards/Healthcare

  • Public and workspace electrical safety in healthcare
  • Electrical safety in hospital wet areas
  • Secondary power sources in healthcare
  • Generator safety
  • Ambulances
  • Field hospital

Key Features

  • Check domestic, industrial, and medical installations
  • Test TT, TN, and IT systems
  • Test single- and multi-phase systems
  • Insulation resistance with a selectable DC test voltage between 50V and 1000V
  • 200mA continuity test with a polarity change for PE conductors
  • 7mA continuity test for PE conductors (without tripping RCDs)
  • Loop/ line impedance measurements
  • Loop impedance test with a Trip Lock RCD function
  • True-RMS voltage measurement
  • True-RMS frequency measurement
  • Phase sequence test
  • Power and harmonics measurements
  • General RCD tests
  • Selectable RCD tests (choose from types AC, A, F, B, B+)
  • Earth resistance measurements using a 3-wire and 2-clamp method
  • First fault leakage current measurements (ISFL)
  • Insulation Monitoring Device (IMD) test
  • Can be used with a Ro-adapter (NOT included) to measure specific earth resistance
  • OPTIONAL true-RMS leakage and load current measurements
  • OPTIONAL illumination measurements
  • AUTO SEQUENCES® for checking TT, TN, and IT earthing systems
  • Automated testing procedure for RCDs
  • On-line voltage monitoring: monitor three voltages in real-time
  • Integrated help screens for on-site referencing
  • Built-in fuse tables for evaluating line and loop impedance results
  • PASS/ FAIL evaluation of fuse and RCD tests
  • Power and harmonics analysis
  • Integrated Bluetooth module
  • Transfer results to a PC via Bluetooth and using the supplied Metrel EuroLink Pro Software
  • Metrel EuroLink Pro Software can be used to create reports
  • Transfer results to an Android device via Bluetooth and Metrel’s free EuroLink Android App
  • Integrated charging unit
  • Supplied with rechargeable NiMH batteries
  • Ideal for testing a variety of electrical installations and systems in accordance with IEC/ EN 61557 specifications

What’s Included?

MI 3102 BT EurotestXE Accessories

  • Metrel MI3102BT Eurotest XE Multifunction Installation Tester
  • 1.5m Plug Commander
  • 3x 1.5m Test Leads
  • 3-wire, 20m Earth Test Set: 1x 4m Test Lead, 2x 20m Test Leads and 2x Test Rods
  • Power Supply Adapter
  • 6x NiMH Rechargeable Batteries
  • Metrel EuroLink Pro Software
  • Blue Test Probe
  • Black test Probe
  • Green Test Probe
  • Blue Crocodile Clip
  • Black Crocodile Clip
  • Green Crocodile Clip
  • RS232-PS/2 Cable
  • USB Cable
  • Soft Carrying Neck Belt
  • Soft Carry Bag
  • Short Instruction Manual
  • Instruction Manual on CD
  • Handbook on CD
  • Calibration Certificate

Metrel MI3102BT Eurotest XE Multifunction Installation Tester Technical Specifications

Function Specification Measuring Range Resolution Accuracy
Continuity Test Current 7 mA 2-wire 0.00 Ω ... 19.99 Ω 0.1 Ω ±(5 % of r. + 5 digits)
20.0 Ω ... 1999 Ω 1 Ω
Test Current 200 mA 2-wire 0.00 Ω ... 19.99 Ω 0.01 Ω ±(3 % of r. + 3 digits)
20.0 Ω ... 199.9 Ω 0.1 Ω ±(5 % of r.)
200.0 Ω ... 1999 Ω 1 Ω ±(5 % of r.)
Insulation Resistance Test Voltage 50/100/250 V 0.00 MΩ ... 19.99 MΩ 0.01 MΩ ±(5 % of r. + 3 digits)
20.0 MΩ ... 99.9 MΩ ±(10 % of r.)
100.0 MΩ ... 199.9 MΩ 0.1 MΩ ±(20 % of r.)
Test Voltage 500/1000 V 0.00 MΩ ... 19.99 MΩ 0.01 MΩ ±(5 % of r. + 3 digits)
20.0 MΩ ... 99.9 MΩ 0.1 MΩ ±(5 % of r.)
200 MΩ ... 999 MΩ 1 MΩ ±(10 % of r.)
RCD RCD Uc 0.00 V ... 19.99 V 0.1 V (-0%/±15 %) of r. ± 10 digits
20.0 V ... 99.9 V (-0%/±15 %) of r.
RCD (t), 0.0 ms ... 40.0 ms 0.1 ms ±1 ms
0.0 ms ... max. time ±3 ms
RCD I Ramp 0.2xI∆N ... 1.1xI∆N (AC) 0.05xI∆N ±0.1xI∆N
0.2xI∆N ... 1.5xI∆N (A), I∆N ≥30 mA)
0.2xI∆N ... 2.2xI∆N (A), I∆N <30 mA)
0.2xI∆N ... 2.2xI∆N (B)
Impedance Zline L-L, L-N Ipsc 0.00 Ω ... 9.99 Ω 0.01 Ω ±(5 % of r. + 5 digits)
10.0 Ω ... 99.9 Ω 0.1 Ω
100 Ω ... 999 Ω 1 Ω ±(10 % of r.)”
1.00 kΩ ... 9.99 kΩ 10 Ω
Zloop L-PE, Ipfc 0.00 Ω ... 9.99 Ω 0.01 Ω ±(5 % of r. + 5 digits)
10.0 Ω ... 99.9 Ω 0.1 Ω
100 Ω ... 999 Ω 1 Ω ±(10 % of r.)
1.00 kΩ ... 9.99 kΩ 10 Ω
Voltage TRMS 0 … 550 V 1 V ±(2 % of r. + 2 digits)
Frequency 0.00 Hz .. 9.99 Hz 0.01 Hz ±(0.2 % of r. + 1 digits)
10.0 Hz ... 499.9 Hz 0.1 Hz
Current TRMS, AC with A1018 0.0 mA ... 99.9 mA 0.1 mA ±(5 % of r. + 5 digits)
100 mA ... 999 mA 1 mA ±(3 % of r. + 3 digits)
1.00 A ... 19.99 A 0.01 A ±(3 % of r.)
TRMS, AC with A1019 0.0 mA ... 99.9 mA 0.1 mA idicative
100 mA ... 999 mA 1 mA ±(5 % of r.)
1.00 A ... 19.99 A 0.01 A ±(3 % of r.)
TRMS, AC/DC with A1391, range=40A 0.00 A ... 1.99 A 0.01 A ±(3 % of r. + 3 digits)
2.00 A ... 19.99 A 0.01 A ±(3 % of r.)
20.0 A ... 39.9 A 0.1 A ±(3 % of r.)
TRMS, AC/DC with A1391, range = 300A 0.00 A ... 19.99 A 0.01 A indicative
20.0 A ... 39.9 A 0.1 A ±(3 % of r. + 5 digits)
40.0 A ... 299.9 A 0.1 A
Earth Resistance 3 wire 0.00 Ω ... 19.99 Ω 0.01 Ω ±(5 % of r. + 5 digits)
20.0 Ω ... 199.9 Ω 0.1 Ω
200.0 Ω ... 9999 Ω 1 Ω
2 clamp 0.00 Ω ... 19.99 Ω 0.01 Ω ±(10 % of r. + 10 digits)
20.0 Ω ... 30.0 Ω 0.1 Ω ±(20 % of r.)
30.1 Ω ... 99.9 Ω 0.1 Ω ±(30 % of r.)
Specific earth resistance 0.0 Ωm … 99.9 Ωm 0.1 Ωm ±(5 % of r.) for Re 1 Ω … 1999kΩ
100 Ωm ... 999 Ωm  1 Ωm
1.00 Ωmk ... 9.99 kΩm 0.01 kΩm ±(10 % of r.) for Re 2 kΩ … 19.99kΩ
10.0 Ωmk ... 99.9 kΩm 0.1 kΩm ±(20 % of r.) for Re > 20 kΩ
First Fault Leakage Current 0.0 mA ... 19.9 mA 0.1 mA ±(5 % of r. + 3 digits)
IMD Test Threshold indicative insulation resistance 5 … 640 kΩ 5 kΩ Indicative values, up to 128 steps
Illuminance Type B 0.01 lux ... 19.99 lux 0.01 lux ±(5 % of r. + 2 digits)
20.0 lux ... 199.9 lux 0.1 lux
200 lux ... 1999 lux 1 lux ±(5 % of r.)
2.00 klux ... 19.99 klux 10 lux
Type C 0.01 lux ... 19.99 lux 0.01 lux ±(10 % of r. + 3 digits)
20.0 lux ... 199.9 lux 0.1 lux
200 lux ... 1999 lux 1 lux ±(10 % of r.)
2.00 klux ... 19.99 klux 10 lux
General Power supply 9 VDC (6x1.5 V battery or accu, size AA)
Overvoltage category 1000 V DC CAT II; 600 V CAT III; 300 V CAT IV
Protection class double insulation
COM port BT, USB, RS232
Weight 1.3 kg
Size ( l x h x w ) 230 x 103 x 115 mm
Accessories related to this product:
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Metrel MI3102BT Eurotest XE Multifunction Installation Tester Kit
Your Rating
Additional Information
SKU MI3102BT
Manufacturer Part Code MI3102BT
Country of Origin Slovenia
International Enquiry