All Metrel Products

Metrel MI3295M Step Contact Voltage Meter Measuring Kit

SKU
MI3295M
Rating:
0%
(0)
Reward Points
:
738
£885.60 £738.00
Lead Time: 1-6 Days Free UK Delivery*
Advice & Support
Price Match Request
Metrel MI3295M Step Contact Voltage Meter Measuring Kit

The Metrel MI3295M Step Contact Voltage Meter Measuring Kit consists of the Metrel MI3295M Step Contact Voltage Meter and a selection of accessories including batteries and test leads. For further information regarding the items included in this kit, please see the ‘What’s Included?’ section.

Metrel MI3295M Step Contact Voltage Meter Description

The Metrel MI3295M Step Contact Voltage Meter is designed for use with the Metrel MI3295S Step Contact Voltage Station (NOT Included). This instrument can serve as a replacement or additional voltage meter for the Metrel MI3295S Step Contact Voltage Station.

As the Metrel MI3295S Station is able to accommodate connections with multiple Metrel MI3295M Meters, the technician or technicians can use this extensive step contact voltage measuring system to quickly analyse voltage distribution around the tested apparatus or installation. The Metrel MI3295M Step Contact Voltage Meter is an autonomous test instrument and can, therefore, be connected to the Metrel MI3925S Step Contact Voltage Station without using long potential leads. This allows for multiple meter connections and adds to the practicality and safety of the Metrel MI3295M Step Contact Voltage Meter.  

Furthermore, when used as part of this measurement system the Metrel MI3295M Step Contact Voltage Meter can be used to check:

  • Step voltages
  • Contact voltages
  • Specific earth resistance
  • Earth resistance
  • Potential
  • Leakage current

Therefore, when used as part of this system, the Metrel MI3295M Step Contact Voltage Meter is ideal for testing and verifying the protective earthing of power stations, substations and other power systems. As such it is particularly well suited to checking earthing funnels, and can also be used to test and verify railway systems and low-voltage installations.

The Metrel MI3295 Step Contact Voltage Measuring System features noise immunity technology that works to eliminate the effects of noise, such as changing earth currents, on measurement results. As a result, this meter can be used to measure step and contact voltages to a high degree of accuracy and reliability, and to a resolution of 10µV.

The Metrel MI3295M Step Contact Voltage Meter includes an extensive internal memory to which test results and parameters may be saved. Its three-level memory has the capacity to store 1500 measurements.

When used with Metrel’s ES Manager or HVLink Pro PC Software Programs (NOT included), the user can download saved test results to his/her PC. These software programs can also be used to conduct measurement analysis, as well as create and print test reports.

The Metrel MI3295M Step Contact Voltage Meter is a useful addition to Metrel’s MI3265S Step Contact Voltage Station or an existing Metrel MI3295 Step Contact Voltage Measuring System. It is ideal for checking and verifying various installations and apparatus used in electrical, industrial and railway power systems.

Metrel MI3295M Step Contact Voltage Meter Key Features

  • Designed for use with the Metrel MI3295S Step Contact Voltage Station (NOT included)
  • Multiple MI3295M Meters can be connected to the MI3295S Station
  • Multiple, connected meters enable quick analysis of voltage distribution
  • Autonomous voltage meter
  • No need for potential leads
  • When used with the MI3295S Station this meter can be used to measure numerous electrical parameters
  • Check step voltages
  • Check contact voltages
  • Measure specific earth resistance
  • Measure earth resistance
  • Check potential
  • Measure leakage current
  • Ideal for testing and verifying the protective earthing of power stations, substations and other power systems
  • Suited to checking earthing funnels
  • Can also be used to test and verify railway systems and low-voltage installations
  • Noise immunity technology
  • Measure step and contact voltages to a high degree of accuracy and reliability and to a resolution of 10µV
  • Test results and parameters are saved to the internal, three-level memory
  • Capacity to store up to 1500 measurements
  • Download results to a PC using Metrel’s ES Manager or HVLink Pro PC Software Programs (NOT included)
  • The above software programs can also be used to analyse results, create reports, and print reports
  • A useful addition to the Metrel MI3295S Station or an existing Metrel MI3295 Step Contact Voltage Measuring System
  • Ideal for checking and verifying installations and apparatus used in railway, electrical and industrial power systems

What’s Included?

  • Metrel MI3295M Step Contact Voltage Meter
  • 2x 3m Test Leads
  • Soft Carrying Bag
  • Soft Carrying Neck Belt
  • NiMH Battery, Type AA, 6 pcs
  • Power Supply Adapter

Metrel MI3295M Step Contact Voltage Meter Technical Specifications

MI3295M Meter Technical Specifications 
Power supply 6 x 1.2 V rechargeable batteries, type AA
Communication ports USB, RS232
Memory 1500 memory locations
Measuring category CAT IV / 50 V
Protection degree IP 40
Display LCD with backlight (128 x 64 dots)
Dimensions 230 x 103 x 115 mm
Weight 1.3 kg
Technical Specifications When Used in Conjunction with a MI3295S to Create a Step Contact Voltage Measuring System 
Function Measuring Range Resolution Accuracy 
Step voltage, Contact voltage (measuring range Um) 0.01 … 19.99 mV 0.01 mV ±(2 % of reading + 2 digits)
20.0 … 199.9 mV 0.1 mV ±(2 % of reading + 2 digits)
200 … 1999 mV 1 mV ±(2 % of reading + 2 digits)
2.00 … 19.99 V 0.01 V ±(2 % of reading + 2 digits)
20.0 V … 59.9 V 0.1 V ±(2 % of reading + 2 digits)
Step voltage, Contact voltage (calculated measuring range U) 0.0 … 199.9 V 0.1 V calculated value*
200 … 999 V 1 V
Test current 55 A max
Test voltage < 55 V
Test frequency 55 Hz
Current 0.00 … 9.99 A 0.01 A ±(3 % of reading + 5 digits)
10.0 … 99.9 A 0.1 A ±(3 % of reading + 3 digits)
Resistance to earth 0.001 … 1.999 Ω 0.001 Ω ±(2 % of reading + 5 digits)
2.00 … 19.99 Ω 0.01 Ω ±(2 % of reading + 5 digits)
20.0 … 99.9 Ω 0.1 Ω ±(2 % of reading + 5 digits)
100.0 … 199.9 Ω 0.1 Ω ±5 % of reading)
Specific earth resistance 0.00 … 9.99 Ωm 0.01 Ωm Calculated value, consider accuracy of Resistance to earth function.
10.0 … 99.9 Ωm 0.1 Ωm
100 … 999 Ωm 1 Ωm
1.00 k … 9.99 kΩm 10 Ωm
10.0 k … 99.9 kΩm 100 Ωm
Potential (MI 3295M) 0.01 … 19.99 mV 0.01 mV ±(2 % of reading + 2 dig)
20.0 … 199.9 mV 0.1 mV
200 … 1999 mV 1 mV
2.00 … 19.99 V 0.01 V
20.0 … 59.9 V 0.1V
Current (MI 3295M) Iron clamp A 1018 1.0 … 99.9 mA 0.1 mA ±(2 % of reading 3 dig)
100 … 999 mA 1 mA
1.00 … 9.99 A 0.01 A
Current (MI 3295M) Flex clamp A 1587 10.0 … 99.9 mA 0.1 mA ±(8 % of reading + 5 dig)
100 … 999 mA 1 mA
1.00 … 9.99 A 0.01 A
10.0 … 30.0 A 0.1 A
10.0 … 50.0 A 0.1 A
Open circuit voltage < 50 VAC
Test current < 7.5 A
Test frequency 55 Hz

0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Metrel MI3295M Step Contact Voltage Meter Measuring Kit
Your Rating
Additional Information
SKU MI3295M
Manufacturer Part Code MI3295M
Country of Origin Slovenia
International Enquiry