Cable / Sheath Fault Locators & Thumpers
Cable locators are used for accurately identifying the presence of underground and overhead insulated line networks. They consist of receivers with signalling equipment and are suitable for use on high voltage systems. Read More about Cable / Sheath Fault Locators & Thumpers
-
Free UK DeliveryMegger EZ-THUMP-4 Portable Fault Location System - 4kV, 15ft Test LeadCall for Pricing
- 4kV DC output
- Cable fault location
- Comes with 15ft test lead
EZT4V3-15T3 -
Free UK DeliveryMegger EZ THUMP-12 Portable Fault Location System - 12kV, 15ft LeadCall for Pricing
- DC testing to 12kV
- Automated fault location
- Wide range of advanced features
EZT12V3-15T3 -
Free UK DeliveryMegger EZ THUMP-4 Portable Fault Location System - 4kV, 50ft Test LeadCall for Pricing
- DC testing to 4kV
- Portable design
- Includes 50ft test lead
EZT4V3-50T3 -
Free UK DeliveryMegger EZ THUMP-12 Portable Fault Location System - 12kV, 50ft LeadCall for Pricing
- 12kV DC output
- 50ft lead included
- Portable design
EZT12V3-50T3 -
Free UK DeliveryMegger HVB10 High Voltage Bridge - Optional Audio Frequency (HVB 10-1-AF)Call for Pricing
- Perform sheath testing
- Reduce downtime
- Standard and high-accuracy modes
HVB10-1012574/5 -
Free UK DeliveryMegger EZ-THUMP 3kV Portable Fault Location SystemCall for Pricing
- Choice of cable length
- ARM pre-location with Multishot Technology
- 7” HiBrite colour display optimised for outdoor visibility
EZT3DV3-XT3 -
Free UK DeliveryMegger T22/13 Burn Down Unit - 15kVCall for Pricing
- For low/medium voltage power cables
- Max burn down current of 25A
- Portable design
T22/13B15KV -
Free UK DeliveryBAUR Shirla Cable Sheath Fault Locator£23,940.00 £19,950.00
- Pre-locate and pin-point cable sheath faults/ cable faults caused by earth contact
- Measure insulation resistance
- Generate pulsed voltage up to 10kV
19950 Reward PointsPrice Match GuaranteeSHIRLA -
Free UK DeliveryBAUR Frida VLF Cable Diagnostics Test Set£28,500.00 £23,750.00
- Test the condition of medium-voltage cables and electrical equipment up to 20kV
- Cable sheath testing
- Dissipation factor and truesinus® indicates the ageing of cables
23750 Reward PointsPrice Match GuaranteeFRIDA -
Free UK DeliveryBAUR Frida TD VLF Cable Diagnostics Test Set w/ Full MWT & Tan DeltaCall for Pricing
- Full MWT combines cable testing and dissipation factor to evaluate cable insulation
- Supports condition-based test duration for Full MWT
- Dissipation factor and truesinus® indicates the ageing of cables
FRIDA-TD -
Free UK DeliveryBAUR Viola VLF Cable Diagnostics Test Set£58,200.00 £48,500.00
- Cable and cable sheath testing on electrical equipment and medium-voltage cables up to 35kV
- Maximum test voltage: 42.5kVrms/ 60kVpeak
- Voltage shapes: DC, VLF rectangular wave and truesinus®
48500 Reward PointsPrice Match GuaranteeVIOLA -
Free UK DeliveryBAUR Viola TD VLF Cable Diagnostics Test Set w/ Full MWT & Tan DeltaCall for Pricing
- Full MWT: combines cable testing with dissipation factor and partial discharge measurements
- Truesinus® technology can be used with dissipation diagnosis to determine cable ageing
- Maximum test voltage: 42.5 kVrms
VIOLA-TD