Beha-Amprobe ProInstall-75-UK MFT with Free 2100-Beta Voltage Tester Kit

Beha-Amprobe ProInstall-75-UK MFT with Free 2100-Beta Voltage Tester Kit
sku: 5010731
MPN: 5010731

Free UK Delivery On Orders Over £40
  • Includes Beha-Amprobe’s ProInstall-75-UK Multifunction Installation Tester and a free 2100-Beta Two Pole Voltage Tester
  • Optimised for testing fixed wiring electrical installations in domestic, commercial and industrial settings
  • Designed for prolonged testing 

Was: £755.00
You Save: £256.00
£499.00 Incl. VAT £598.80

Beha-Amprobe Spring Offer - Limited Time Only

Was: £755.00
You Save: £256.00
£499.00 Incl. VAT £598.80
Members earn 998 points

Do you have a question or found it cheaper? Contact us

  • 30M R2 Extension Wander Test Lead (PVC Cable Reel)
    £29.99
  • CK Tools AVIT 5 x Insulated Screwdriver Set
    £14.74
  • Silvertronic 3 Wire Silicone Test Lead Set
    £21.95
Description

Beha-Amprobe ProInstall-75-UK MFT with Free 2100-Beta Voltage Tester Kit Details

Amprobe ProInstall-75-UK MFT with Free 2100-Beta Voltage Tester Kit

*** Please note that this offer is available for a limited time only and is subject to availability or while stocks last. ***

The Beha-Amprobe ProInstall-75-UK MFT with Free 2100-Beta Voltage Tester Kit includes:

  • 1x Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester
  • 1x FREE Beha-Amprobe 2100-Beta Two Pole Voltage Tester
  • 1x Test Lead Set
  • 1x Probe Tip Set
  • 1x Remote Test Probe
  • 1x Zero Adapter
  • 1x Fused Test Probe Set with Instruction Manual
  • 1x Mains Test Cord
  • 1x Carrying Strap
  • 1x User Manual on CD-ROM
  • 1x Quick Reference Card
  • 1x Calibration Certificate
  • 2x Set of 3 AA Batteries
  • 1x Soft Case
  • 1x Test Adapter for EV Charging Stations with an EVC-20 Cable (UK Socket)

Please see the descriptions below for further details regarding Beha-Amprobe's multifunction tester and voltage tester.

Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester Description

The Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester can be used to verify that fixed wiring electrical installations, whether domestic, commercial or industrial, have been installed correctly and in accordance with IEC 60364, HD 384 requirements.

 As such it is able to test the following electrical parameters:

  • AC voltage and frequency
  • Wiring polarity
  • Insulation resistance
  • Continuity and resistance
  • Loop and line resistance
  • Prospective earth fault current (PEFC/IK)
  • Prospective short circuit current (PSC/IK)
  • RCD switching time
  • RCD tripping level (ramp test)

The Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester also includes a phase sequence indicator and can be used to test pulse current sensitive RCDs (type A). Moreover, this instrument includes a variable RCD current mode, allowing the user to tailor the multifunction installation tester to the application. Alternatively, the user can run an automatic RCD test sequence. The results of RCD tests are clearly indicated using a PASS/ FAIL indicator on the large, backlit display with a wide viewing angle.

Further to this, the Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester includes high-current loop tests which can be tailored to ensure that they do not trip RCDs. This improves testing efficiency as loop impedance can be measured without having to perform time-consuming checks designed to avoid RCDs.

Adding to this product’s adaptability is its variety of insulation test voltages and selectable voltage measurements between L-N, L-PE and N-PE. Furthermore, the Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester is supplied with slim reach probes allowing the user to easily measure hard-to-access panels/ places, again adding to this instrument’s versatility and expanding its scope-for-use.

With regards to the accuracy of its measurements, the Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester is equipped with a Zero Adapter which will compensate for the resistance present in test leads. Further to this, its Auto-Null function can be used to subtract test lead resistance from measurements and will store these values in its onboard memory even after powering down. It is also programmed to perform self-tests ensuring that it will always provide the user with a high-level of performance.

Measurements indicated on the Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester’s display are written to a high resolution, adding to the accuracy of this instrument. It is possible to view mains voltage and frequency measurements simultaneously via the Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester’s large, backlit, dual display.

Also adding to the practicality of this instrument is its padded neck strap and compact, ergonomic design; features that make this tester easy to handle and hold, and, therefore, well suited to prolonged periods of testing. Moreover, its simple-to-operate controls add to the efficiency and ease with which tests and checks can be performed.

The Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester is comprehensive, efficient and adaptable; it is ideal for checking fixed wiring electrical installations in domestic, commercial and industrial environments.

Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester Key Features

  • Verify that fixed wiring electrical installations have been installed correctly and in accordance with IEC 60364, HD 384 requirements
  • Suitable for testing domestic, commercial or industrial electrical installations
  • Able to check a multitude of electrical parameters
  • AC voltage and frequency
  • Wiring polarity
  • Insulation resistance
  • Continuity and resistance
  • Loop and line resistance
  • Prospective earth fault current (PEFC/IK)
  • Prospective short circuit current (PSC/IK)
  • RCD switching time
  • RCD tripping level (ramp test)
  • Phase sequence indicator
  • Test pulse current sensitive RCDs (type A)
  • Variable RCD current mode
  • Automatic RCD test sequence
  • PASS/ FAIL indicator for RCD tests
  • Large, backlit, dual display with a wide viewing angle
  • High-current loop tests
  • Loop tests can be adapted to ensure they do not trip RCDs
  • Variety of insulation test voltages
  • Selectable voltage measurements between L-N, L-PE and N-PE
  • Supplied with slim reach probes for accessing hard-to-reach panels/ places
  • Zero Adapter for compensating for test leads
  • Auto-Null removes test lead resistance from measurements and stores these values to the onboard memory
  • Self-tests
  • Measurements are displayed to a high-resolution
  • View mains voltage and frequency simultaneously via the display
  • Padded neck strap
  • Compact, ergonomic design
  • Easy to hold and handle
  • Ideal for all day testing
  • Simple-to-operate controls
  • Detachable test leads for easy replacement
  • A comprehensive, efficient and adaptable tester
  • Ideal for checking fixed wiring electrical installations in domestic, commercial and industrial environments

FREE Beha-Amprobe 2100-Beta Two Pole Voltage Tester Description

Like the above Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester, the free Beha-Amprobe 2100-Beta Two Pole Voltage Tester is suitable for use in domestic, commercial and industrial environments. It can be used to test for and measure AC and DC voltages to 690V as well as check circuits for continuity.

The Beha-Amprobe 2100-Beta Two Pole Voltage Tester will automatically determine whether the detected voltage is AC or DC and will also indicate its polarity. The Beha-Amprobe 2100-Beta Two Pole Voltage Tester includes an LED display for indicating the voltage range and an LCD display for indicating the voltage reading. Furthermore, the tester will alert the user via an audible alarm when it has detected voltages in excess of 50V AC or 120V DC.

The Beha-Amprobe 2100-Beta Two Pole Voltage Tester also features a dedicated LED for indicating continuity.  This tester will perform continuity tests automatically.

In addition to testing for voltage and continuity, the Beha-Amprobe 2100-Beta Two Pole Voltage Tester can be used to perform single-pole tests for checking phase polarity, as well as detect single-phase voltage using the main probe, when performing this check the Beha-Amprobe 2100-Beta Two Pole Voltage Tester will issue an audible and visual alert when a voltage is detected. This tester is also capable of two pole phase rotation indication.

Moreover, the Beha-Amprobe 2100-Beta Two Pole Voltage Tester can be used to trip test 10mA and 30mA RCDs. It features two push buttons which allow the user to trip these components remotely in order to ascertain whether they have been wired correctly. Furthermore, when both buttons are pressed the instrument is in low impedance mode which eliminates the effects of ghost voltages on the measurements, adding to this instrument's accuracy.

Conversely, when neither of these buttons is pressed the Beha-Amprobe 2100-Beta Two Pole Voltage Tester remains in high impedance mode which prevents the accidental tripping of RCDs and ELCBs, thereby adding to the safety of this instrument.

In addition to this, the Beha-Amprobe 2100-Beta Two Pole Voltage Tester features a safety rating of CAT III 690V / CAT IV 600 V.  It also has an IP rating of 64, ensuring that it is resistant to splashes and dust. These ratings, combined with its GS approval and reinforced components make the Beha-Amprobe 2100-Beta Two Pole Voltage Tester suitable for use in a variety of environments, including rugged industrial settings.

Further to this, the Beha-Amprobe 2100-Beta Two Pole Voltage Tester includes an extra-long 1.5m test lead with a wear indicator, which adds to both the safety of this instrument and the ease with which difficult-to-access circuits can be tested. 

Moreover, the supplied test probe protector cover tips can also be used to open UK electrical safety outlets, again improving testing efficiency. These GS38 protective probe caps along with the 4mm test probe extensions can be stored on the Beha-Amprobe 2100-Beta Two Pole Voltage Tester, ensuring that they can be easily accessed when needed.

The Beha-Amprobe 2100-Beta Two Pole Voltage Tester is a comprehensive, rugged and easy-to-use voltage and continuity tester. It is ideal for checking domestic, commercial and industrial circuits.

FREE Beha-Amprobe 2100-Beta Two Pole Voltage Tester Key Features

  • Suitable for use in domestic, commercial and industrial environments
  • Test for and measure AC and DC voltage to 690V
  • Check circuits for continuity
  • Automatically identifies the voltage type (AC/DC) and its polarity
  • LED display for indicating the voltage range
  • An LCD display for indicating the voltage reading
  • Audible alarm when voltages in excess of 50V AC and 120V DC have been detected
  • LED continuity indicator
  • Automatically tests for continuity
  • Single pole tests for checking phase polarity
  • Single –phase voltage detection using the main probe (issues an audible and visual alert when a voltage is detected)
  • Two pole phase rotation indication
  • Trip test 10mA and 30mA RCDs
  • Low impedance mode eliminates the effects of ghost voltages
  • High impedance mode prevents accidental tripping of RCDs and ELCBs
  • Safety rating: CAT III 690V/ CAT IV 600V
  • IP64
  • Reinforced components
  • GS approval
  • 1.5m test lead with a wear indicator
  • GS38 protective probe caps and 4mm probe extensions can be stored on the instrument
  • Test probe protector cover tips can be used to open UK electrical safety outlets
  • A comprehensive, rugged and easy-to-use voltage and continuity tester
  • Ideal for checking domestic, commercial and industrial circuits

What’s Included?

  • 1x Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester
  • 1x FREE Beha-Amprobe 2100-Beta Two Pole Voltage Tester
  • 1x Test Lead Set
  • 1x Probe Tip Set
  • 1x Remote Test Probe
  • 1x Zero Adapter
  • 1x Fused Test Probe Set with Instruction Manual
  • 1x Mains Test Cord
  • 1x Carrying Strap
  • 1x User Manual on CD-ROM
  • 1x Quick Reference Card
  • 1x Calibration Certificate
  • 2x Set of 3 AA Batteries
  • 1x Soft Case
  • 1x Test Adapter for EV Charging Stations with an EVC-20 Cable (UK Socket)
Technical Specs

Part Code: 5010731

Beha-Amprobe ProInstall-75-UK MFT with Free 2100-Beta Voltage Tester Kit Technical Specifications

Please find below the technical specifications for the products included in this promotion. 

Beha-Amprobe ProInstall-75-UK Multifunction Installation Tester Technical Specifications 

General Specifications
Size 10cm (L) x 25cm (W) x 12.5cm (H)
Weight (with Batteries) 1.3kg
Battery 6 x AA. Alkaline supplied. Usable with 1.2V NiCd or NiMH batteries (not included)
Battery Life (Typical) 200 hours idling
Fuse T3.15 A, 500 V, 1.5 kA 6.3 x 32 mm (PN 2030852)
Operating Temperature -10 to 40°C
Storage Temperature -10 to 60°C indefinitely (to -40°C for 100 hours)
Relative Humidity Non-condensing 80%: 10 to 35°C
70%: 35 to 40°C
Operating Altitude 0 to 2000m
Shock, Vibration Vibration to Class 3 per Mil-Prf-28800F 1 meter drop test, six sides, oak floor
Sealing IP40
EMC Complies with EN61326-1: 2006
Safety Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ ISA
-s82.02.01 2000 and CAN/CSA c22.2 No.1010 2nd edition Overvoltage
Category III (CAT III), 500 V Measurement Category III is for
measurements performed in the building installation. CAT IV, 300V.
Examples are distribution panels, circuit breakers, wiring and cabling.
Performance EN61557-1, EN61557-2, EN61557-3, EN61557-4, EN61557-5,
EN61557-6, EN61557-7 Second edition. EN61557-10 First edition.
Maximum Voltage Between Any Terminal and Earth Ground 500V
Surge Protection 6 kV peak per EN 61010-1 Ed. 2.0 (2001-02)
AC Voltage Measurement (V)
Display Range Resolution Accuracy 50Hz to 60Hz Input Impedance Overload Protection
0 to 500V 0.1V 0.8% + 3 3.3MΩ 600V RMS
Continuity Testing (RLo)
Display Range (Autoranging) Resolution Open Circuit Voltage Accuracy Range RLo Test Current
0 to 20Ω 0.01Ω >4V ±(1.5% + 3 digits) 7.5 210mA
35 100mA
200Ω 0.1Ω >4V ±(1.5% + 3 digits) 240 20mA
2000Ω >4V ±(1.5% + 3 digits) 2000 2mA
Test Probe Zeroing Press the (zero) button to zero the test probe. Can subtract up to 2 Ω of lead resistance. Error message for >2 Ω.
Live Circuit Detection Inhibits test if terminal voltage >10 V ac detected prior to initiation of test.
Insulation Resistance Measurements (Riso)
Test Voltages 250, 500, 1000V
Accuracy of Test Voltage (At Rated Test Current) +10%, -0%
Test Voltage Insulation Resistance Range Resolution Test Current Accuracy
50V 10 kΩ to 50 MΩ 0.01 MΩ 1mA @ 50kΩ ±(3 % + 3 digits)
100V 100 kΩ to 20 MΩ 0.01 MΩ 1mA @ 100kΩ ±(3 % + 3 digits)
20 MΩ to 100 MΩ 0.1 MΩ ±(3 % + 3 digits)
250V 10 kΩ to 20 MΩ 0.01 MΩ 1mA @ 250kΩ ±(1.5% + 3 digits)
20 MΩ to 200 MΩ 0.1 MΩ ±(1.5% + 3 digits)
500V 10 kΩ to 20 MΩ 0.01 MΩ 1mA @ 500kΩ ±(1.5% + 3 digits)
20 MΩ to 200 MΩ 0.1 MΩ ±(1.5% + 3 digits)
200 MΩ to 500 MΩ 1 MΩ ±10%
1000V 100 kΩ to 200 MΩ 0.01 MΩ 1mA @ 1MΩ ±(1.5% + 3 digits)
200 MΩ to 1000 MΩ 1 MΩ ±10%
Auto Discharge Discharge time constant <0.5 second for C=1μF or less
Live Circuit Detection Inhibits test if terminal voltage >30V prior to initiation of test
Maximum Capacitive Load Operable with up to the 5μF load
Loop and Line Impedance (Zl), No Trip and Hi Current Modes RCD/FI
Mains Input Voltage Range 100 to 500V AC (50/60Hz)
Input Connection (Soft Key Selection) Loop Impedance: Phase to Earth
Line Impedance: Phase to Neutral
Limit on Consecutive Tests Automatic shutdown when internal components are too hot.
There is also a thermal shutdown for RCD tests
Maximum Test Current at 400V 20A sinusoidal for 10ms
Maximum Test Current at 230V 12A sinusoidal for 10ms
Range Resolution Accuracy
10Ω 0.001Ω Hi Current Ω: ±2% +15 digits)
20Ω 0.01Ω

No Trip Mode: ±3% + 6 digits

Hi Current Mode: ±(2% + 4 digits)

200Ω 0.1Ω No-Trip Mode: ±(3%)
Hi Current Mode: ±2%
2000Ω ±6%**
Notes * Valid for resistance of neutral circuit <20 Ω and up to a system phase angle of 30°. Test leads must be zeroed before testing.
** Valid for mains voltage >200 V.
Prospective Earth Fault Current Test (PSCI/Ik)
Resolution and Units Resolution Units
IK < 1000A 1A
IK > 1000A 0.1kA
Computation Prospective Earth Fault Current (PEFC/IK) or Prospective Short Circuit Current (PSC/IK) determined by dividing
measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
Range 0 to 10 kA or 0 to 50 kA (See Power-On Options earlier in this manual)
Accuracy Determined by accuracy of loop resistance and mains voltage measurements.
RCD Testing
Types Tested AC1, AC, A4, A, G2, S3, G, S
Test Signals  
AC The waveform is a sinewave starting at zero crossing, polarity determined by phase selection (0° phase starts with low to high zero
crossing, 180° phase starts with high to low zero crossing). The magnitude of the test current is IΔn x Multiplier for all tests.
A The waveform is a half wave rectified sinewave starting at zero, polarity determined by phase selection (0° phase starts with low to
high zero crossing,180° phase starts with high to low zero crossing). The magnitude of the test current is 2.0 x IΔn (rms) x Multiplier
for all tests for IΔn = 0.01A. The magnitude of the test current is 1.4 x IΔn (rms) x Multiplier for all tests for all other IΔn ratings.
B Smooth DC current according to EN61557-6 Annex A
Tripping Speed Test (ΔT)
Current settings** Multiplier Current Accuracy
10–30–100–300–500–1000 mA -VAR x 1/2 +0 %, -10 % of test current
10–30–100–300–500–1000 mA -VAR x 1 +10 %, -0 %
10–30–100 mA x 5 +10 %, -0 %
Note, 1 1000 mA type AC only. 700 mA maximum type A in VAR mode, not available for type B.
Current Multiplier *RCD type Measurement Range Trip Time Accuracy
Europe UK
x 1/2 G 310 ms 2000 ms ±(1 % Reading + 1 ms)
x 1/2 S 510 ms 2000 ms ±(1 % Reading + 1 ms)
x 1 G 310 ms 310 ms ±(1 % Reading + 1 ms)
x 1 S 510 ms 510 ms ±(1 % Reading + 1 ms)
x 5 G 50 ms 50 ms ±(1 % Reading + 1 ms)
x 5 S 160 ms 160 ms ±(1 % Reading + 1 ms)
Notes  *G – General, no delay
*S – Time delay
Maximum Trip Time
The RCD √ symbol switches on when testing the RCD trip time if the trip time meets the following conditions.
RCD I Δ N Trip Time Limits
AC G, A, B x 1 Less than 300 ms
AC, G - S type, A - S type, B - type x 1 Between 130 ms and 500 ms
AC G, A, B x 5 Less than 40 ms
AC, G - S type, A - S type, B - type x 5 Between 50 ms and 150 ms
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
Current Range Step Size Dwell Time Measurement Accuracy
Type G Type S
30 % to 110 % of RCD rated current1 10 % of IΔN 2 300 ms/step 500 ms/step ±5 %

Notes:

1 30 % to 150 % for Type A IΔN >10 mA

30 % to 210 % for Type A IΔN = 10 mA

20 % to 210 % for Type B

Specified trip current ranges (EN 61008-1):

50 % to 100 % for Type AC

35 % to 140 % for Type A (>10 mA)

35 % to 200 % for Type A (≤10 mA)

50 % to 200 % for Type B 2 5% for Type B

Phase Sequence Indication
Icon icon Phase Sequence indicator is active
Display of Phase Sequence Displays “1-2-3” in digital display field for correct sequence. Displays “3-2-1” for incorrect phase. Dashes in place of a number indicate a valid determination could not be made.
Mains Input Voltage Range (phase-tophase) 100 to 500 V

Amprobe 2100-Beta Two Pole Voltage Tester Technical Specifications 

Specifications  2100-Beta

Voltage Test

LED Voltage Range

12…690 V AC/DC

LED Indicator

±12, ±24, 50, 120, 230, 400, 690 V

LED Tolerances

acc. To EN 61243-3:2010

LCD Voltage Range

6…690 V AC/DC

LCD Resolution

1 V

LCD Tolerance

± (3% rdg + 3 LSD)

LED and LCD Response Time

< 1s

Frequency Range

DC,  16 2/3 Hz…400 Hz

Acoustic Indication

≥ 50 V AC, ≥ 120 V DC

Voltage Detection

Automatic (AC/DC)

Polarity Detection

Full Range

Range Detection

Automatic

Current I

(load buttons not activated)

≤3.5 mA AC/DC at 690 V AC/DC

Internal Load

(load buttons not activated)

Approximately 2.4 W at 690 V AC/DC

Test Current Switchable Load

(load buttons activated)

≤250 mA AC/DC at 690 V AC/DC

Switchable Load

(load buttons activated)

Approximately 170 W at 690 V AC/DC

Automatic Power ON

LED: >10 V (activated load buttons)

 LCD: >10V

Impedance at ELV level

270 kΩ @ 50 VAC

Impedance at ELV level and switched load

5 kΩ @ 50 VAC

Trip Test RCD (earth leakage circuit breaker)

Test Current Switchable Load

(load buttons activated)

>30 mAAC at 230 VAC

Single Pole Phase Test

Voltage Range

100…690 VAC against earth

Frequency Range

40Hz… 70Hz

Acoustic Indication

Yes

Indication

Red LED

Continuity Test (Rx)/ Diode Test

Range

0….500 kΩ

Tolerance

0% to +50%

Test Current

<5 μA

Acoustic Indication

Yes

Diode Test

Yes

Indication

Yellow LED

Overvoltage Protection

690 V AC/DC

Automatic Power ON

< 500 kΩ

Phase Rotation Indication

Voltage Range

170...690 V AC phase to phase

Frequency Range

40…70 Hz

Indication

Green LEDs

Non-Contact Voltage Indication/ Electric Field (NCV/EF)

Voltage Range

-

Frequency Range

-

Indication

_

Data Hold

Data Hold

Only voltage measurements (12…690V AC/DC)

Measurement Illumination Area/ Torch Light

Torch Light

White LED

Backlight

White LED

General Specifications

Operation Time (DT)

30s

Recovery Time

240s

Operating Temperature

-15°C to +55°C

Storage Temperature

-15°C to +55°C

Humidity

Max. 95% RH

Operating Altitude

Up to 2000m

Safety Rating (Overall Voltage Category)

CAT IV / 600V, CAT III / 690V

Pollution Degree

2

Protection Degree

IP64

Safety Regulations

IEC 61243-3:2009, EN 61243-3:2010, DIN VDE 0682-401:2011

Approvals, Compliance

GS mark from TÜV Rheinland, CE

Power Supply

Battery 2 x 1.5V (AAA/ IEC LR03)

Power Consumption

Approximately 90mA

Battery Lifetime

More than 10000 measurements (<5 s/ per measurement)

Dimensions (HxWxD)

Approximately 280 x 78 x 35 mm (11.0 x 3.1 x 1.4 in)

Weight

Approximately 320 g (0.71 lb)